Abstract

The aim of this prospective study was to evaluate the usefulness of stroke volume variation (SVV) derived from NICOM® to predict fluid responsiveness in the prone position. Forty adult patients undergoing spinal surgery in the prone position were included in this study. We measured SVV from NICOM® (SVVNICOM) and FloTrac™/Vigileo™ systems (SVVVigileo), and pulse pressure variation (PPV) using automatic (PPVauto) and manual (PPVmanual) calculations at four time points including supine and prone positions, and before and after fluid loading of 6 ml kg−1 colloid solution. Fluid responsiveness was defined as an increase in the cardiac index from Vigileo™ of ≥12 %. There were 19 responders and 21 non-responders. Prone positioning induced a significant decrease in SVVNICOM, SVVVigileo, PPVauto, and PPVmanual. However, all of these parameters successfully predicted fluid responsiveness in the prone position with area under the receiver-operator characteristic curves for SVVNICOM, SVVVigileo, PPVauto, and PPVmanual of 0.78 [95 % confidence interval (CI) 0.62–0.90, P = 0.0001], 0.79 (95 % CI 0.63–0.90, P = 0.0001), 0.76 (95 % CI 0.6–0.88, P = 0.0006), and 0.84 (95 % CI 0.69–0.94, P < 0.0001), respectively. The optimal cut-off values were 12 % for SVVNICOM, SVVVigileo, and PPVauto, and 10 % for PPVmanual. SVV from NICOM® successfully predicts fluid responsiveness during surgery in the prone position. This totally non-invasive technique for assessing individual functional intravenous volume status would be useful in a wide range of surgeries performed in the prone position.

Original languageEnglish
Pages (from-to)397-405
Number of pages9
JournalJournal of Clinical Monitoring and Computing
Volume31
Issue number2
DOIs
StatePublished - 1 Apr 2017

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Cardiac output
  • Fluids therapy
  • Heart
  • Intraoperative
  • Monitoring
  • Prone position
  • Spinal surgery

Fingerprint

Dive into the research topics of 'Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position'. Together they form a unique fingerprint.

Cite this