TY - JOUR
T1 - Usefulness of whole-blood interferon-γ assay and interferon-γ enzyme-linked immunospot assay in the diagnosis of active pulmonary tuberculosis
AU - Kang, Young Ae
AU - Lee, Hye Won
AU - Hwang, Seung Sik
AU - Um, Sang Won
AU - Han, Sung Koo
AU - Shim, Young Soo
AU - Yim, Jae Joon
PY - 2007/9
Y1 - 2007/9
N2 - Purpose: The aim of this study was to evaluate the usefulness of the whole-blood interferon-γassay (enzyme-linked immunosorbent assay [ELISA]) and interferon-γ enzyme-linked immunospot assay (ELISPOT) based on early secretory antigenic target 6 and culture filtrate protein 10 in the diagnosis of active pulmonary tuberculosis (TB) in routine clinical practice. Method: We conducted a prospective study enrolling 144 participants with suspected pulmonary TB in a tertiary referral hospital in Seoul, South Korea, to investigate the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of these tests. Clinical assessment, tuberculin skin test (TST), whole-blood interferon-γ ELISA (Quanti-FERON-TB Gold [QFT-G]; Cellestis Ltd; Victoria, Australia), and an ELISPOT assay (T SPOT.TB; Oxford Immunotec; Oxford, UK) were performed. Test results were compared with the final confirmed diagnoses. Results: Active pulmonary TB was diagnosed in 67 of 144 participants (47%). Sensitivities of QFT-G and T SPOT.TB for active pulmonary TB were 89% (95% confidence interval [CI], 79 to 96%) and 92% (95% CI, 83 to 97%), respectively; and specificities were 49% (95% CI, 37 to 61%) and 47% (95% CI, 36 to 59%). NPVs of QFT-G (84%; 95% CI, 69 to 93%) and T SPOT.TB (87%; 95% CI, 73 to 96%) were higher than that of TST (64%; 95% CI, 51 to 76%) [p = 0.001 and p < 0.001, respectively]. Conclusion: High NPVs of QFT-G and T SPOT.TB for the diagnosis of active TB suggest the supplementary role of these tests for the diagnostic exclusion of active TB, although the low PPV limits their usefulness in routine clinical practice in South Korea, where the prevalence of latent TB infection is considerable.
AB - Purpose: The aim of this study was to evaluate the usefulness of the whole-blood interferon-γassay (enzyme-linked immunosorbent assay [ELISA]) and interferon-γ enzyme-linked immunospot assay (ELISPOT) based on early secretory antigenic target 6 and culture filtrate protein 10 in the diagnosis of active pulmonary tuberculosis (TB) in routine clinical practice. Method: We conducted a prospective study enrolling 144 participants with suspected pulmonary TB in a tertiary referral hospital in Seoul, South Korea, to investigate the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of these tests. Clinical assessment, tuberculin skin test (TST), whole-blood interferon-γ ELISA (Quanti-FERON-TB Gold [QFT-G]; Cellestis Ltd; Victoria, Australia), and an ELISPOT assay (T SPOT.TB; Oxford Immunotec; Oxford, UK) were performed. Test results were compared with the final confirmed diagnoses. Results: Active pulmonary TB was diagnosed in 67 of 144 participants (47%). Sensitivities of QFT-G and T SPOT.TB for active pulmonary TB were 89% (95% confidence interval [CI], 79 to 96%) and 92% (95% CI, 83 to 97%), respectively; and specificities were 49% (95% CI, 37 to 61%) and 47% (95% CI, 36 to 59%). NPVs of QFT-G (84%; 95% CI, 69 to 93%) and T SPOT.TB (87%; 95% CI, 73 to 96%) were higher than that of TST (64%; 95% CI, 51 to 76%) [p = 0.001 and p < 0.001, respectively]. Conclusion: High NPVs of QFT-G and T SPOT.TB for the diagnosis of active TB suggest the supplementary role of these tests for the diagnostic exclusion of active TB, although the low PPV limits their usefulness in routine clinical practice in South Korea, where the prevalence of latent TB infection is considerable.
KW - Culture filtrate protein 10
KW - Diagnosis
KW - Early secretory antigenic target 6
KW - Interferon-γ
KW - Tuberculosis
UR - https://www.scopus.com/pages/publications/35448993476
U2 - 10.1378/chest.06-2805
DO - 10.1378/chest.06-2805
M3 - Article
C2 - 17505029
AN - SCOPUS:35448993476
SN - 0012-3692
VL - 132
SP - 959
EP - 965
JO - Chest
JF - Chest
IS - 3
ER -