Abstract
This study investigated the feasibility of ultrasonic bonding of a rigid printed circuit board (RPCB) to a flexible printed circuit board (FPCB) with a non-conductive film (NCF) for improving the long-term reliability and lowering the manufacturing cost. Peel tests of the joints were carried out with increasing bonding time to optimize the bonding condition. High-temperature storage and thermal cycling tests were carried out to evaluate the reliability. The RPCB was successfully bonded to the FPCB with NCF using a transverse ultrasonic bonding. The optimum time taken for bonding was 3 sec. The joints with NCF showed a good reliability after the high-temperature storage test at 125°C for 1,000 h and the thermal cycling test for 1,000 cycles.
| Original language | English |
|---|---|
| Pages (from-to) | 341-350 |
| Number of pages | 10 |
| Journal | Journal of Adhesion |
| Volume | 85 |
| Issue number | 6 |
| DOIs | |
| State | Published - 2009 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 9 Industry, Innovation, and Infrastructure
Keywords
- Flexible printed circuit board (FPCB)
- Non-conductive film
- Peel test
- Reliability test
- Rigid printed circuit board (RPCB)
- Ultrasonic bonding
Fingerprint
Dive into the research topics of 'Ultrasonic bonding of electrodes of rigid and flexible printed circuit boards with non-conductive film (NCF)'. Together they form a unique fingerprint.Cite this