N2 - Remote photoplethysmography (rPPG) is a technology that extracts blood volume pulse (BVP) signals by analyzing the wavelength differences of light reflected from a person’s skin using devices such as RGB and infrared cameras. This technology enables the measurement and estimation of various physiological signals, including heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), respiratory rate, and oxygen saturation. In this study, we overcame the limitations of existing rPPG methods by constructing a custom RGB-rPPG dataset. The dataset was collected from 14 subjects using an RGB camera (a standard webcam), wearable device, and sphygmomanometer. The leave-one-subject-out (LOSO) approach was applied for model training to predict SBP and DBP, while HR was estimated using a fast Fourier transform (FFT). The average mean absolute error for SBP/DBP prediction and HR estimation were 4.55 (±2.7660) mmHg, 1.84 (±1.6064) mmHg, and 6.91 (±8.0319) bpm, respectively. These results demonstrate that the constructed RGB-rPPG dataset and the proposed method are effective for predicting physiological signs.
AB - Remote photoplethysmography (rPPG) is a technology that extracts blood volume pulse (BVP) signals by analyzing the wavelength differences of light reflected from a person’s skin using devices such as RGB and infrared cameras. This technology enables the measurement and estimation of various physiological signals, including heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), respiratory rate, and oxygen saturation. In this study, we overcame the limitations of existing rPPG methods by constructing a custom RGB-rPPG dataset. The dataset was collected from 14 subjects using an RGB camera (a standard webcam), wearable device, and sphygmomanometer. The leave-one-subject-out (LOSO) approach was applied for model training to predict SBP and DBP, while HR was estimated using a fast Fourier transform (FFT). The average mean absolute error for SBP/DBP prediction and HR estimation were 4.55 (±2.7660) mmHg, 1.84 (±1.6064) mmHg, and 6.91 (±8.0319) bpm, respectively. These results demonstrate that the constructed RGB-rPPG dataset and the proposed method are effective for predicting physiological signs.
KW - deep learning
KW - digital health care
KW - real-time physiological signals prediction
KW - Remote photoplethysmography
UR - https://www.scopus.com/pages/publications/105002312393
U2 - 10.1109/BCI65088.2025.10931624
DO - 10.1109/BCI65088.2025.10931624
M3 - Conference contribution
AN - SCOPUS:105002312393
T3 - International Winter Conference on Brain-Computer Interface, BCI
BT - 13th International Winter Conference on Brain-Computer Interface, BCI 2025
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 13th International Winter Conference on Brain-Computer Interface, BCI 2025
Y2 - 24 February 2025 through 26 February 2025
ER -