TY - GEN
T1 - Time-Series Forecasting
T2 - 2022 IEEE Sensors Conference, SENSORS 2022
AU - Ortiz, Bengie L.
AU - Miller, Evan
AU - Dallas, Tim
AU - Chong, Jo Woon
N1 - Publisher Copyright:
© 2022 IEEE.
PY - 2022
Y1 - 2022
N2 - Biometric Authentication (BA) is a process where behavioral and physiological inputs are used to determine the identity of individuals. Photoplethysmogram (PPG) is commonly used to provide physiological information of patients, such as heart rate and breathing rate. With technological advances, smartphones can provide PPG information without any external hardware. In this paper, we propose a BA system based on PPG readings. Features were selected by considering possible unique physiological factors during the period when PPG signals are acquired. We adopted the eXtreme Gradient Boosting (XGBoost) algorithm as a classification model. As performance metrics, we considered accuracy, specificity, and equal error rate (EER). Experimental results show that the average training accuracy, specificity, and EER values are 97.36%, 99.94%, and 0.06%, respectively, while the average testing accuracy, specificity, and EER values are 96.38%, 99.57%, and 0.43%, respectively.
AB - Biometric Authentication (BA) is a process where behavioral and physiological inputs are used to determine the identity of individuals. Photoplethysmogram (PPG) is commonly used to provide physiological information of patients, such as heart rate and breathing rate. With technological advances, smartphones can provide PPG information without any external hardware. In this paper, we propose a BA system based on PPG readings. Features were selected by considering possible unique physiological factors during the period when PPG signals are acquired. We adopted the eXtreme Gradient Boosting (XGBoost) algorithm as a classification model. As performance metrics, we considered accuracy, specificity, and equal error rate (EER). Experimental results show that the average training accuracy, specificity, and EER values are 97.36%, 99.94%, and 0.06%, respectively, while the average testing accuracy, specificity, and EER values are 96.38%, 99.57%, and 0.43%, respectively.
KW - Biometric Authentication
KW - Equal Error Rate
KW - eXtreme Gradient Boosting
KW - Motion and Noise Artifacts
KW - Photoplethysmogram
UR - https://www.scopus.com/pages/publications/85144052577
U2 - 10.1109/SENSORS52175.2022.9967189
DO - 10.1109/SENSORS52175.2022.9967189
M3 - Conference contribution
AN - SCOPUS:85144052577
T3 - Proceedings of IEEE Sensors
BT - 2022 IEEE Sensors, SENSORS 2022 - Conference Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 30 October 2022 through 2 November 2022
ER -