TY - JOUR
T1 - The Fast and Easy Way for Double-Lumen Tube Intubation
T2 - Individual Angle- Modification
AU - Min, Jeong Jin
AU - Lee, Jong Hwan
AU - Kang, Se Hee
AU - Kim, Eunhee
AU - Lee, Sangmin M.
AU - Cho, Jong Ho
AU - Kim, Hong Kwan
N1 - Publisher Copyright:
© 2016 Min et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2016/8
Y1 - 2016/8
N2 - To find the faster and easier way than the existing intubating technique for double-lumen tube, we modified the angle of double-lumen tube according to an individual's upper airway anatomy and compared the time needed and the number of attempts for successful intubation between individually angle-modified and non-modified double-lumen tubes. Adult patients undergoing elective thoracic surgery were randomly allocated in either non-anglemodified (Group N, n = 54) or angle-modified (Group M, n = 54) groups. During mask ventilation in the sniffing position, angle-modification was performed in Group M as follows: The distal tip of the tube was placed at the level of the cricoid cartilage and the shaft was bent at the intersection of the oral and pharyngeal axes estimated from the patient's surface anatomy. The time needed and the number of attempts for successful intubation and Cormack and Lehane (C-L) grade were recorded. Overall median intubation time (sec) was significantly shorter in Group M than in Group N [10.2 vs. 15.1, P<0.001]. In addition, Group M showed the shorter median intubation time (sec) in C-L grades I-III [8.2 vs. 11.1 in C-L grade I, (P = 0.003), 10.3 vs. 15.3 in II, (P = 0.001), and 11.8 vs. 27.9 in III, (P<0.001), respectively]. Moreover, all intubation was successfully performed at the first attempt in patients with C-L grades I-III in Group M (P = 0.027). Our study showed an individual angle-modification would be useful for the fast and easy intubation of double-lumen tube in patients with C-L grades I-III.
AB - To find the faster and easier way than the existing intubating technique for double-lumen tube, we modified the angle of double-lumen tube according to an individual's upper airway anatomy and compared the time needed and the number of attempts for successful intubation between individually angle-modified and non-modified double-lumen tubes. Adult patients undergoing elective thoracic surgery were randomly allocated in either non-anglemodified (Group N, n = 54) or angle-modified (Group M, n = 54) groups. During mask ventilation in the sniffing position, angle-modification was performed in Group M as follows: The distal tip of the tube was placed at the level of the cricoid cartilage and the shaft was bent at the intersection of the oral and pharyngeal axes estimated from the patient's surface anatomy. The time needed and the number of attempts for successful intubation and Cormack and Lehane (C-L) grade were recorded. Overall median intubation time (sec) was significantly shorter in Group M than in Group N [10.2 vs. 15.1, P<0.001]. In addition, Group M showed the shorter median intubation time (sec) in C-L grades I-III [8.2 vs. 11.1 in C-L grade I, (P = 0.003), 10.3 vs. 15.3 in II, (P = 0.001), and 11.8 vs. 27.9 in III, (P<0.001), respectively]. Moreover, all intubation was successfully performed at the first attempt in patients with C-L grades I-III in Group M (P = 0.027). Our study showed an individual angle-modification would be useful for the fast and easy intubation of double-lumen tube in patients with C-L grades I-III.
UR - https://www.scopus.com/pages/publications/84984861394
U2 - 10.1371/journal.pone.0161434
DO - 10.1371/journal.pone.0161434
M3 - Article
C2 - 27537372
AN - SCOPUS:84984861394
SN - 1932-6203
VL - 11
JO - PLoS ONE
JF - PLoS ONE
IS - 8
M1 - e0161434
ER -