T1 - The comparison of joint kinematic error using the absolute and relative coordinate systems for human gait
AU - Rim, Yong Hoon
AU - Choi, Ahn Ryul
AU - Lee, Sang Sik
AU - Min, Kyoung Kee
AU - Keum, Dong Hyuk
AU - Choi, Chang Hyun
AU - Mun, Joung Hwan
PY - 2009/7
Y1 - 2009/7
N2 - Minimizing artifacts from skin movement is vital for acquiring more accurate kinematic data in human movement analysis. There are several stages that cause skin movement artifacts and these stages depend on the selection of the reference system, the error reduction method and the coordinate system in clinical gait analysis. Due to residual errors, which are applied to the Euler and Bryant angle methods in each stage, significant cumulative errors are generated in the motion analysis procedure. Thus, there is currently a great deal of research focusing on reducing kinematic errors through error reduction methods and kinematic error estimations in relation to the reference system. However, there have been no studies that have systematically examined the effects of the selected coordinate system on the estimation of kinematic errors, because most of these previous studies have been mainly concerned with the analysis of human movement using only the human models that are provided in the commercial 3D motion capture systems. Therefore, we have estimated the differences between the results of human movement analyses using an absolute coordinate system and a relative coordinate system during a gait, in order to establish which system provides a more accurate kinematic analysis at the ankle joint. Six normal adult subjects with no neurological or orthopedic conditions, lower extremity injuries, or recent history of lower extremity surgery were used in this study. The analysis was conducted at a walking speed of 1.35m/s. For the clinical estimation, we used a cardinal plane based on the segmental reference system and the differences were plotted on the planes. From this analysis, when a relative coordinate system was in the gait analysis, the average kinematic error occurring during the gait was determined to be 13.58mm, which was significantly higher than the error generated with an absolute coordinate system. Therefore, although the relative coordinate system can also be used to calculate the ankle joint center during the clinical gait analysis, the absolute coordinate system should be employed in order to obtain more accurate joint kinematic data. In addition, the results from this study can be used as a basis to select an appropriate coordinate system with regards to the diagnostic accuracy level required for various kinds of gait disorders.
AB - Minimizing artifacts from skin movement is vital for acquiring more accurate kinematic data in human movement analysis. There are several stages that cause skin movement artifacts and these stages depend on the selection of the reference system, the error reduction method and the coordinate system in clinical gait analysis. Due to residual errors, which are applied to the Euler and Bryant angle methods in each stage, significant cumulative errors are generated in the motion analysis procedure. Thus, there is currently a great deal of research focusing on reducing kinematic errors through error reduction methods and kinematic error estimations in relation to the reference system. However, there have been no studies that have systematically examined the effects of the selected coordinate system on the estimation of kinematic errors, because most of these previous studies have been mainly concerned with the analysis of human movement using only the human models that are provided in the commercial 3D motion capture systems. Therefore, we have estimated the differences between the results of human movement analyses using an absolute coordinate system and a relative coordinate system during a gait, in order to establish which system provides a more accurate kinematic analysis at the ankle joint. Six normal adult subjects with no neurological or orthopedic conditions, lower extremity injuries, or recent history of lower extremity surgery were used in this study. The analysis was conducted at a walking speed of 1.35m/s. For the clinical estimation, we used a cardinal plane based on the segmental reference system and the differences were plotted on the planes. From this analysis, when a relative coordinate system was in the gait analysis, the average kinematic error occurring during the gait was determined to be 13.58mm, which was significantly higher than the error generated with an absolute coordinate system. Therefore, although the relative coordinate system can also be used to calculate the ankle joint center during the clinical gait analysis, the absolute coordinate system should be employed in order to obtain more accurate joint kinematic data. In addition, the results from this study can be used as a basis to select an appropriate coordinate system with regards to the diagnostic accuracy level required for various kinds of gait disorders.
KW - Absolute coordinate system
KW - Gait analysis
KW - Joint kinematic error
KW - Relative coordinate system
KW - Segmental reference system
UR - https://www.scopus.com/pages/publications/84866181082
U2 - 10.1007/s12206-008-0818-6
DO - 10.1007/s12206-008-0818-6
M3 - Article
AN - SCOPUS:84866181082
SN - 1738-494X
VL - 23
SP - 161
EP - 169
JO - Journal of Mechanical Science and Technology
JF - Journal of Mechanical Science and Technology
IS - 1
ER -