Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: An experimental study in ex vivo bovine and in vivo porcine livers

  • Jihoon Cha
  • , Young Sun Kim
  • , Hyunchul Rhim
  • , Hyo K. Lim
  • , Dongil Choi
  • , Min Woo Lee
  • Sungkyunkwan University

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: The aims of this study were to evaluate the performance of radiofrequency (RF) ablation using a new type of internally cooled RF electrode with an adjustable active tip in an ex vivo bovine liver model and to determine if adjustment of the active tip length makes a significant difference in the size of ablation zone in an in vivo porcine liver model. Materials and methods: We performed ex vivo experiments by producing 100 RF ablation zones in 40 extracted bovine livers using a new type of RF electrode that had an adjustable active tip (adjustable electrode) (n = 50) and a conventional internally cooled electrode (conventional electrode) (n = 50). We also performed an in vivo study with the induction of 30 RF ablation zones in ten living porcine livers using the adjustable electrode with 2 cm (n = 15) and 3 cm (n = 15) active tip adjustments. The size (three perpendicular diameters), volume and ratio of the two axes of the ablation zone were macroscopically evaluated and were compared. Results: For the ex vivo study using a 2 cm and 3 cm active tip, there was no significant difference in ablation performance between the use of conventional and adjustable electrodes. For the use of the conventional and adjustable electrodes with 2 cm active tip, respectively, the volume was 10.75 ± 3.43 cm3 versus 10.64 ± 3.25 cm3 and the ratio of the two axes was 1.24 ± 0.16 versus 1.30 ± 0.17; p > 0.05. For the use of the conventional and adjustable electrodes with 3 cm active tip, respectively, the volume was 21.17 ± 4.09 cm3 versus 21.48 ± 3.51 cm3 and the ratio of the two axes was 1.28 ± 0.12 versus 1.28 ± 0.07; p > 0.05. For the in vivo study using the adjustable electrode, the ablation volume with the 2 cm adjustment was significantly smaller as compared to the 3 cm adjustment (5.29 ± 2.22 cm3 versus 13.44 ± 4.25 cm3; p < 0.05) with no statistical difference for the ratio of the two axes (1.44 ± 0.22 versus 1.49 ± 0.24; p > 0.05). Conclusion: Using a new type of internally cooled RF electrode, we could induce different volumes of the RF ablation zone by means of adjusting the length of the exposed active tip, where performance was similar to the use of a conventional internally cooled RF electrode.

Original languageEnglish
Pages (from-to)516-521
Number of pages6
JournalEuropean Journal of Radiology
Volume77
Issue number3
DOIs
StatePublished - Mar 2011

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Hepatocellular carcinoma
  • Liver
  • Metastasis
  • Radiofreqeuncy ablation

Fingerprint

Dive into the research topics of 'Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: An experimental study in ex vivo bovine and in vivo porcine livers'. Together they form a unique fingerprint.

Cite this