TY - JOUR
T1 - Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
AU - Yang, Chan Min
AU - Lim, Dong Hui
AU - Hwang, Sungsoon
AU - Hyun, Joo
AU - Chung, Tae Young
N1 - Publisher Copyright:
© 2018 The Author(s).
PY - 2018/3/7
Y1 - 2018/3/7
N2 - Background: To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally. Methods: This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+ 2.75 D) was implanted in a dominant eye, and TECNIS® ZLB00 (+ 3.25 D) was implanted in a non-dominant eye. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and manifest refraction (MR) values were measured at 1 month and 3 months postoperatively. At the 3-month follow-up, defocus curve, contrast sensitivity, and reading performance were evaluated. Quality of vision, overall satisfaction, and spectacle independence were evaluated by questionnaire. Results: Postoperative binocular UDVA, visual acuity at 80 cm, 60 cm, 50 cm, 43 cm, 33 cm were - 0.08 ± 0.10, 0.12 ± 0.14, 0.09 ± 0.09, 0.07 ± 0.11, 0.14 ± 0.09, 0.25 ± 0.11 logMAR. The binocular defocus curve showed an extended range of good visual acuity with sharp vision being observed from 0 D to - 2.50 D defocus (logMAR≤0.1). Reading performance was significantly improved compared to baseline. All patients were spectacle-free at distance, and 94.74% of the patients did not require glasses for near and intermediate vision. Conclusions: Mix-and-match implantation of diffractive multifocal IOLs with different add power provides an excellent wide range of vision, as well as high levels of visual quality and patient satisfaction. Trial registration: ClinicalTrials.gov, NCT02556944, https://clinicaltrials.gov/show/NCT02556944
AB - Background: To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally. Methods: This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+ 2.75 D) was implanted in a dominant eye, and TECNIS® ZLB00 (+ 3.25 D) was implanted in a non-dominant eye. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and manifest refraction (MR) values were measured at 1 month and 3 months postoperatively. At the 3-month follow-up, defocus curve, contrast sensitivity, and reading performance were evaluated. Quality of vision, overall satisfaction, and spectacle independence were evaluated by questionnaire. Results: Postoperative binocular UDVA, visual acuity at 80 cm, 60 cm, 50 cm, 43 cm, 33 cm were - 0.08 ± 0.10, 0.12 ± 0.14, 0.09 ± 0.09, 0.07 ± 0.11, 0.14 ± 0.09, 0.25 ± 0.11 logMAR. The binocular defocus curve showed an extended range of good visual acuity with sharp vision being observed from 0 D to - 2.50 D defocus (logMAR≤0.1). Reading performance was significantly improved compared to baseline. All patients were spectacle-free at distance, and 94.74% of the patients did not require glasses for near and intermediate vision. Conclusions: Mix-and-match implantation of diffractive multifocal IOLs with different add power provides an excellent wide range of vision, as well as high levels of visual quality and patient satisfaction. Trial registration: ClinicalTrials.gov, NCT02556944, https://clinicaltrials.gov/show/NCT02556944
UR - https://www.scopus.com/pages/publications/85043267143
U2 - 10.1186/s12886-018-0735-0
DO - 10.1186/s12886-018-0735-0
M3 - Article
C2 - 29514611
AN - SCOPUS:85043267143
SN - 1471-2415
VL - 18
JO - BMC Ophthalmology
JF - BMC Ophthalmology
IS - 1
M1 - 73
ER -