Paced QRS axis as a predictor of pacing-induced left ventricular dysfunction

  • Sung Hwan Kim
  • , Yong Seog Oh
  • , Gi Byoung Nam
  • , Kee Joon Choi
  • , Jae Seok Park
  • , Sang Weon Park
  • , Seung Jung Park
  • , Young Keun On
  • , June Soo Kim
  • , Woo Seung Shin
  • , Ji Hoon Kim
  • , Sung Won Jang
  • , Man Young Lee
  • , You Ho Kim
  • , Tai Ho Rho

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Purpose: The selection of the optimal right ventricular (RV) pacing site remains unclear. We hypothesized that a normal paced QRS axis would provide a physiological ventricular activation and lead to a better long-term outcome.

Methods: We evaluated 187 patients who underwent a permanent pacemaker implantation and were dependent on RV pacing. The pacing sites were classified as the apex and non-apex according to the chest radiography. A paced QRS axis was defined as that between −30° and 90°. Preservation of the left ventricular (LV) systolic function was defined as that with a <10 % decrease in the ejection fraction after the pacemaker implantation.

Results: The median follow-up period was 5.8 years (interquartile 3.9–9.0). Radiographically, the RV leads were located in the apex (n = 148, 79 %) or non-apex (n = 39, 21 %). In the electrocardiogram, normal paced and abnormal paced QRS axes were observed in 28 patients (15 %) and 159 patients (85 %), respectively. The LV ejection fraction was decreased in the patients with an abnormal paced QRS axis (−10 ± 10 %, P < 0.001), but not in those with a normal axis (0 ± 6 %, P = 0.80). The electrocardiographic determinant differentiated a preserved LV function (95 % vs. 35 %, log-rank P = 0.04). Among the patients with radiographically non-apical pacing, a normal paced QRS axis was an additional meaningful predictor of a preserved LV function after the pacemaker implantation (95 % vs. 24 %, log-rank P = 0.002).

Conclusion: Compared with the radiographic method, a normal paced QRS axis was associated with a preserved LV function.

Original languageEnglish
Pages (from-to)223-229
Number of pages7
JournalJournal of Interventional Cardiac Electrophysiology
Volume41
Issue number3
DOIs
StatePublished - 9 Dec 2014

Keywords

  • Electrocardiography
  • Heart failure
  • Pacemaker
  • Pacing-induced cardiomyopathy

Fingerprint

Dive into the research topics of 'Paced QRS axis as a predictor of pacing-induced left ventricular dysfunction'. Together they form a unique fingerprint.

Cite this