Optische Qualität dreier trifokaler Intraokularlinsenmodelle: Vergleich an der optischen Bank

Translated title of the contribution: Optical quality of three trifocal intraocular lens models: An optical bench comparison

R. Khoramnia, T. M. Yildirim, T. Tandogan, S. Liebing, G. Łabuz, C. Y. Choi, G. Auffarth

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Background: Knowledge of the optical quality of different trifocal intraocular lenses (IOL) is important in customized patient care. Objective: Different trifocal IOL were compared regarding their optical quality. Materials and methods: We analyzed the FineVision (PhysIOL, Liège, Belgium), the AT LISA tri 839MP (Zeiss, Oberkochen, Germany), and the AcrySofIQ PanOptix (Alcon, Fort Worth, TX, USA) with a power of +21D for the distance using the OptiSpheric IOL PRO optical bench (Trioptics, Wedel, Germany). The additions for the near and intermediate distances were as follows: +3.5D/+1.75D (FineVision), +3.33D/+1.66D (AT LISA tri), and + 3,25D/+ 2,17D (PanOptix). We evaluated the modulation transfer function (MTF) at a spatial frequency of 50lp/mm and the Strehl ratio using 3‑ (photopic) and 4.5-mm (mesopic) apertures. Results: The MTF at 50 lp/mm (FineVision/AT Lisa tri/PanOptix) at the far focus was 0.373/0.399/0.400 (3-mm aperture) and 0.512/0.311/0.243 (4.5-mm aperture). At the intermediate focus, the MTF was 0.162/0.147/0.153 (3-mm aperture) and 0.092/0.125/0.137 (4.5-mm aperture). The MTF at the near focus was 0.229/0.192/0.404 (3-mm aperture) and 0.217/0.212/0.169 (4.5-mm aperture). The Strehl ratio was 0.335/0.298/0.370 (3-mm aperture) and 0.243/0.180/0.270 (4.5-mm aperture) at the far focus. At intermediate distances, the Strehl ratio was 0.189/0.185/0.162 (3-mm aperture) and 0.099/0.097/0.114 (4.5-mm aperture). The Strehl ratio was 0.305/0.283/0.464 (3-mm aperture) and 0.177/0.181/0.155 (4.5-mm aperture) at the near focus. Conclusion: Evaluation of the three trifocal IOL models at the optical bench could show distinct peaks at the far, intermediate, and near focus. The results were comparable in terms of optical performance.

Translated title of the contributionOptical quality of three trifocal intraocular lens models: An optical bench comparison
Original languageGerman
Pages (from-to)21-28
Number of pages8
JournalOphthalmologe
Volume115
Issue number1
DOIs
StatePublished - 1 Jan 2018
Externally publishedYes

Keywords

  • Cataract extraction
  • Lenses
  • Optical devices
  • Pseudophakia
  • Visual acuity

Fingerprint

Dive into the research topics of 'Optical quality of three trifocal intraocular lens models: An optical bench comparison'. Together they form a unique fingerprint.

Cite this