Optimization of dual layer phoswich detector consisting of LSO and Lu YAP for small animal PET

  • Yong Hyun Chung
  • , Yong Choi
  • , Gyuseong Cho
  • , Yearn Seong Choe
  • , Kyung Han Lee
  • , Byung Tae Kim
  • Sungkyunkwan University
  • Korea Advanced Institute of Science and Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Phoswich detectors for small animal PET have been developed to measure the depth of interaction and to improve resolution performances. The aim of this study was to perform simulations to design the optimum lengths of crystals composing a dual layer phoswich detector. A simulation tool, the Geant4 Application for Tomographic Emission (GATE), was used and validated against a commercially available small animal PET using a dual layer phoswich detector. The newly designed small PET system employed cerium doped lutetium oxyorthosilicate (LSO) - cerium doped lutetium-yttrium aluminum perovskite (LuYAP) phoswich detector modules, which consisted of 8 × 8 arrays of dual layer crystals, with a 2 × 2 mm sensitive area, coupled to a Hamamatsu R7600-00-M64 position sensitive photomultiplier tube (PSPMT). The sensitivities and variations of the radial resolutions were simulated by varying the length of the LSO front layer from 0 to 10 mm, while the total length (LSO+LuYAP) was fixed to 20 mm for 10 and 19 cm diameter ring scanners. The results support the validity of the simulation tool. The radial resolution uniformity was markedly improved using the depth of interaction (DOI) information, and the optimal lengths of the crystal layers for minimizing the variation of the radial resolutions also existed. In the 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm, over 8 cm field of view (FOV), while the sensitivity was higher than 7.4% for the LSO 5 mm : Lu YAP 15 mm phoswich detector. The resolution variations were minimized to less than 3.6 mm, over 16 cm FOV, using a LSO 6 mm : Lu YAP 14 mm phoswich detector for the 19 cm ring scanner. In this study, the optimal length of the dual layer phoswich detector was derived to achieve a high and uniform radial resolution.

Original languageEnglish
Pages (from-to)217-221
Number of pages5
JournalIEEE Transactions on Nuclear Science
Volume52
Issue number1 I
DOIs
StatePublished - Feb 2005

Keywords

  • Depth-of-interaction
  • Phoswich detector
  • Small animal PET