TY - JOUR
T1 - Mismatches between the Number of Installed Automated External Defibrillators and the Annual Rate of Automated External Defibrillator Use among Places
AU - Oh, Je Hyeok
AU - Cho, Gyu Chong
AU - Ryoo, Seung Mok
AU - Han, So Hyun
AU - Woo, Seon Hee
AU - Jang, Yong Soo
AU - Cho, Youngsuk
AU - Sim, Minseob
AU - Kim, Oh Hyun
N1 - Publisher Copyright:
© The Author(s), 2021. Published by Cambridge University Press on behalf of the World Association for Disaster and Emergency Medicine.
PY - 2021/4
Y1 - 2021/4
N2 - Aim: In South Korea, the law concerning automated external defibrillators (AEDs) states that they should be installed in specific places including apartment complexes. This study was conducted to investigate the current status and effectiveness of installation and usage of AEDs in South Korea. Methods: Installation and usage of AEDs in South Korea is registered in the National Emergency Medical Center (NEMC) database. Compared were the installed number, usage, and annual rate of AED use according to places of installation. All data were obtained from the NEMC database. Results: After excluding AEDs installed in ambulances or fire engines (n = 2,003), 36,498 AEDs were registered in South Korea from 1998 through 2018. A higher number of AEDs were installed in places required by the law compared with those not required by the law (20,678 [56.7%] vs. 15,820 [43.3%]; P <.001). Among them, 11,318 (31.0%) AEDs were installed in apartment complexes. The overall annual rate of AED use was 0.38% (95% CI, 0.33-0.44). The annual rate of AED use was significantly higher in places not required by the law (0.62% [95% CI, 0.52-0.72] versus 0.21% [95% CI, 0.16-0.25]; P <.001). The annual rate of AED use in apartment complexes was 0.13% (95% CI, 0.08-0.17). Conclusion: There were significant mismatches between the number of installed AEDs and the annual rate of AED use among places. To optimize the benefit of AEDs in South Korea, changes in the policy for selecting AED placement are needed.
AB - Aim: In South Korea, the law concerning automated external defibrillators (AEDs) states that they should be installed in specific places including apartment complexes. This study was conducted to investigate the current status and effectiveness of installation and usage of AEDs in South Korea. Methods: Installation and usage of AEDs in South Korea is registered in the National Emergency Medical Center (NEMC) database. Compared were the installed number, usage, and annual rate of AED use according to places of installation. All data were obtained from the NEMC database. Results: After excluding AEDs installed in ambulances or fire engines (n = 2,003), 36,498 AEDs were registered in South Korea from 1998 through 2018. A higher number of AEDs were installed in places required by the law compared with those not required by the law (20,678 [56.7%] vs. 15,820 [43.3%]; P <.001). Among them, 11,318 (31.0%) AEDs were installed in apartment complexes. The overall annual rate of AED use was 0.38% (95% CI, 0.33-0.44). The annual rate of AED use was significantly higher in places not required by the law (0.62% [95% CI, 0.52-0.72] versus 0.21% [95% CI, 0.16-0.25]; P <.001). The annual rate of AED use in apartment complexes was 0.13% (95% CI, 0.08-0.17). Conclusion: There were significant mismatches between the number of installed AEDs and the annual rate of AED use among places. To optimize the benefit of AEDs in South Korea, changes in the policy for selecting AED placement are needed.
KW - automated external defibrillators
KW - electric defibrillation
KW - law
KW - out-of-hospital cardiac arrest
KW - South Korea
UR - https://www.scopus.com/pages/publications/85099406088
U2 - 10.1017/S1049023X20001508
DO - 10.1017/S1049023X20001508
M3 - Article
C2 - 33436139
AN - SCOPUS:85099406088
SN - 1049-023X
VL - 36
SP - 183
EP - 188
JO - Prehospital and Disaster Medicine
JF - Prehospital and Disaster Medicine
IS - 2
ER -