Skip to main navigation Skip to search Skip to main content

In vitro and in vivo biosafety analysis of resorbable polyglycolic acid-polylactic acid block copolymer composites for spinal fixation

  • Seung Kyun Yoon
  • , Jin Ho Yang
  • , Hyun Tae Lim
  • , Young Wook Chang
  • , Muhammad Ayyoob
  • , Xin Yang
  • , Young Jun Kim
  • , Han Seung Ko
  • , Jae Young Jho
  • , Dong June Chung
  • Sungkyunkwan University
  • Hanyang University
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

Abstract

Herein, spinal fixation implants were constructed using degradable polymeric materials such as PGA–PLA block copolymers (poly(glycolic acid-b-lactic acid)). These materials were reinforced by blending with HA-g-PLA (hydroxyapatite-graft-poly lactic acid) and PGA fiber before being tested to confirm its biocompatibility via in vitro (MTT assay) and in vivo animal experiments (i.e., skin sensitization, intradermal intracutaneous reaction, and in vivo degradation tests). Ev-ery specimen exhibited suitable biocompatibility and biodegradability for use as resorbable spinal fixation materials.

Original languageEnglish
Article number29
Pages (from-to)1-16
Number of pages16
JournalPolymers
Volume23
Issue number1
DOIs
StatePublished - Jan 2021

Keywords

  • Bioresorbable
  • Composite
  • In vivo degradation test
  • MTT assay
  • PGA–PLA block copolymer

Fingerprint

Dive into the research topics of 'In vitro and in vivo biosafety analysis of resorbable polyglycolic acid-polylactic acid block copolymer composites for spinal fixation'. Together they form a unique fingerprint.

Cite this