Impact of Optimized Procedure-Related Factors in Drug-Eluting Balloon Angioplasty for Treatment of In-Stent Restenosis

  • Tae Min Rhee
  • , Joo Myung Lee
  • , Eun Seok Shin
  • , Doyeon Hwang
  • , Jonghanne Park
  • , Ki Hyun Jeon
  • , Hack Lyoung Kim
  • , Han Mo Yang
  • , Jung Kyu Han
  • , Kyung Woo Park
  • , Joo Yong Hahn
  • , Bon Kwon Koo
  • , Sang Hyun Kim
  • , Hyo Soo Kim
  • Seoul National University
  • Sungkyunkwan University
  • University of Ulsan
  • Sejong General Hospital

Research output: Contribution to journal › Article › peer-review

Abstract

Objectives: The aim of this study was to investigate the impact of optimizing procedure-related factors during drug-eluting balloon (DEB) angioplasty on clinical outcomes of drug-eluting stent in-stent restenosis (ISR). Background: Although DEB angioplasty is recommended as a reasonable option for ISR, recurrent target lesion failure (TLF) still occurs in many patients after DEB angioplasty. Methods: Consecutive patients with drug-eluting stent ISR treated with DEB (SeQuent Please) were collected from 4 centers in Korea. The primary outcome was 2-year TLF. Procedure-related modifiable independent predictors for TLF and their best cutoff values were determined. Results: In a total of 256 patients (309 lesions), TLF occurred in 52 patients (20.3%). Modifiable independent predictors of TLF among procedure-related factors were residual diameter stenosis after lesion preparation (residual percentage diameter stenosis [%DS]), DEB-to-stent ratio (BSR), and DEB inflation time (Tinflation), whose best cutoff values were 20%, 0.91, and 60 s, respectively. TLF rates were significantly higher in groups with residual %DS ≥20% (34.7% vs. 12.5%; adjusted hazard ratio: 2.15; 95% confidence interval: 1.86 to 2.48; p < 0.001), BSR ≤0.91 (46.4% vs. 21.9%; adjusted hazard ratio: 2.02; 95% confidence interval: 1.75 to 2.34; p < 0.001), and Tinflation ≤60 s (26.2% vs. 14.0%; adjusted hazard ratio: 1.82; 95% confidence interval: 1.36 to 2.45; p < 0.001). When classifying ISR lesions by combination of procedure-related factors, TLF occurred in 8.3% in the fully optimized procedure group (residual %DS <20%, BSR >0.91, and Tinflation >60 s) and 66.7% in the nonoptimized group (residual %DS ≥20%, BSR ≤0.91, and Tinflation ≤60 s) (p < 0.001). Conclusions: Residual %DS after lesion preparation, BSR, and Tinflation were the only modifiable procedure-related factors in DEB angioplasty. Fully optimized DEB angioplasty with optimal lesion preparation, prolonged inflation, and sufficient dilation may play an important role in reducing TLF after DEB angioplasty.

Original languageEnglish
Pages (from-to)969-978
Number of pages10
JournalJACC: Cardiovascular Interventions
Volume11
Issue number10
DOIs
StatePublished - 28 May 2018

Keywords

  • drug-eluting balloon
  • in-stent restenosis
  • paclitaxel-coated balloon
  • percutaneous coronary intervention
  • target lesion failure