Abstract
Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. Material and Methods: Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.50 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 excellent to 4 poor enhancement). Non-parametric statistical approaches were used to compare the two groups. Results: The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median 460 HU, range 216791 HU) compared with iomeprol 400 (median 435 HU, range 195758 HU) (P 0.006). The median image quality score of coronary arterial segments was 1 (range 12) for both groups (P 0.84). Conclusion: The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370.
| Original language | English |
|---|---|
| Pages (from-to) | 982-989 |
| Number of pages | 8 |
| Journal | Acta Radiologica |
| Volume | 51 |
| Issue number | 9 |
| DOIs | |
| State | Published - Nov 2010 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Contrast agent
- Coronary arteries
- CT angiography
Fingerprint
Dive into the research topics of 'Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver