TY - JOUR
T1 - Hepatic outflow obstruction at middle hepatic vein tributaries or inferior right hepatic veins after living donor liver transplantation with modified right lobe graft
T2 - Comparison of CT and Doppler ultrasound
AU - Hye, Jeon Hwang
AU - Kim, Kyoung Won
AU - Woo, Kyoung Jeong
AU - So, Yeon Kim
AU - Song, Gi Won
AU - Hwang, Shin
AU - Lee, Sung Gyu
PY - 2009/9
Y1 - 2009/9
N2 - OBJECTIVE. The objective of our study was to compare CT and Doppler ultrasound in the diagnosis of hepatic outflow obstruction at the middle hepatic vein (MHV) tributaries and inferior right hepatic veins (RHVs) after living donor liver transplantation (LDLT) with modified right lobe grafts. MATERIALS AND METHODS. Thirty-seven venographies were performed in 36 patients after LDLT with modified right lobe grafts, evaluating 51 MHV tributaries and 25 inferior RHVs. They were classified as obstructed or nonobstructed. On Doppler ultrasound or CT, flow patterns of the MHV tributaries and inferior RHVs or the relative parenchymal attenuation, enhancement, and opacification of these veins were evaluated for the diagnosis of hepatic outflow obstruction. McNemar tests were performed to compare the diagnostic values of Doppler ultrasound and CT. RESULTS. On the basis of hepatic venography, 33 MHV tributaries were categorized as obstructed and 18 as nonobstructed, and 16 inferior RHVs were categorized as obstructed and nine as nonobstructed. For the diagnosis of MHV tributary obstruction, Doppler ultrasound was more sensitive and accurate, although less specific, than CT (97% vs 39%, respectively, p < 0.001; 86% vs 61%, p = 0.0209; 67% vs 100%, p = 0.0412). Similarly, Doppler ultrasound was more sensitive (94% vs 31%, respectively) and accurate (84% vs 56%) than CT, although less specific (67% vs 100%), for the diagnosis of inferior RHV obstruction, with a statistical significance only for sensitivity (p = 0.002, 0.092, and 0.248, respectively). CONCLUSION. Doppler ultrasound is more sensitive and accurate than CT for the detection of obstruction at the MHV tributaries and inferior RHVs in patients after LDLT using modified right lobe grafts. Although current CT criteria produce high specificity and may reduce unnecessary invasive venographies, optimal CT criteria with acceptable sensitivity should be reestablished.
AB - OBJECTIVE. The objective of our study was to compare CT and Doppler ultrasound in the diagnosis of hepatic outflow obstruction at the middle hepatic vein (MHV) tributaries and inferior right hepatic veins (RHVs) after living donor liver transplantation (LDLT) with modified right lobe grafts. MATERIALS AND METHODS. Thirty-seven venographies were performed in 36 patients after LDLT with modified right lobe grafts, evaluating 51 MHV tributaries and 25 inferior RHVs. They were classified as obstructed or nonobstructed. On Doppler ultrasound or CT, flow patterns of the MHV tributaries and inferior RHVs or the relative parenchymal attenuation, enhancement, and opacification of these veins were evaluated for the diagnosis of hepatic outflow obstruction. McNemar tests were performed to compare the diagnostic values of Doppler ultrasound and CT. RESULTS. On the basis of hepatic venography, 33 MHV tributaries were categorized as obstructed and 18 as nonobstructed, and 16 inferior RHVs were categorized as obstructed and nine as nonobstructed. For the diagnosis of MHV tributary obstruction, Doppler ultrasound was more sensitive and accurate, although less specific, than CT (97% vs 39%, respectively, p < 0.001; 86% vs 61%, p = 0.0209; 67% vs 100%, p = 0.0412). Similarly, Doppler ultrasound was more sensitive (94% vs 31%, respectively) and accurate (84% vs 56%) than CT, although less specific (67% vs 100%), for the diagnosis of inferior RHV obstruction, with a statistical significance only for sensitivity (p = 0.002, 0.092, and 0.248, respectively). CONCLUSION. Doppler ultrasound is more sensitive and accurate than CT for the detection of obstruction at the MHV tributaries and inferior RHVs in patients after LDLT using modified right lobe grafts. Although current CT criteria produce high specificity and may reduce unnecessary invasive venographies, optimal CT criteria with acceptable sensitivity should be reestablished.
KW - CT
KW - Doppler ultrasound
KW - Hemodynamics
KW - Hepatic outflow obstruction
KW - Liver transplantation
KW - Living donor related liver transplantation
UR - https://www.scopus.com/pages/publications/69949095853
U2 - 10.2214/AJR.08.2145
DO - 10.2214/AJR.08.2145
M3 - Article
C2 - 19696288
AN - SCOPUS:69949095853
SN - 0361-803X
VL - 193
SP - 745
EP - 751
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 3
ER -