TY - JOUR
T1 - Fine-tuning of MXene-nickel oxide-reduced graphene oxide nanocomposite bioelectrode
T2 - Sensor for the detection of influenza virus and viral protein
AU - Manohara Reddy, Y. Veera
AU - Shin, Jae Hwan
AU - Hwang, Jaehyeon
AU - Kweon, Dae Hyuk
AU - Choi, Chang Hyung
AU - Park, Kyeongsoon
AU - Kim, Sun Ki
AU - Madhavi, G.
AU - Yi, Hyunmin
AU - Park, Jong Pil
N1 - Publisher Copyright:
© 2022 Elsevier B.V.
PY - 2022/10/15
Y1 - 2022/10/15
N2 - Influenza viruses can cause epidemics through inter-human transmission, and the social consequences of viral transmission are incalculable. Current diagnostics for virus detection commonly relies on antibodies or nucleic acid as recognition reagent. However, a more advanced and general method for the facile development of new biosensors is increasing in demand. In this study, we report the fabrication of an ultra-sensitive peptide-based nanobiosensor using a nickel oxide (NiO)–reduced graphene oxide (rGO)/MXene nanocomposite to detect active influenza viruses (H1N1 and H5N2) and viral proteins. The sensing mechanism is based on the signal inhibition, the specific interaction between H1N1 (QMGFMTSPKHSV) and H5N1 (GHPHYNNPSLQL) binding peptides anchored on the NiO–rGO/MXene/glassy carbon electrode (GCE) surface and the viral surface protein hemagglutinin (HA) is the critical factor for the decrease in the peak current of the sensor. In this strategy, the NiO–rGO/MXene nanocomposite results in synergistic signal effects, including electrical conductivity, porosity, electroactive surface area, and active site availability when viruses are deposited on the electrode. Based on these observations, the results showed that the developed nanobiosensor was capable of highly sensitive and specific detection of their corresponding influenza viruses and viral proteins with a very low detection limit (3.63 nM of H1N1 and 2.39 nM for H5N1, respectively) and good recovery. The findings demonstrate that the proposed NiO–rGO/MXene-based peptide biosensor can provide insights for developing a wide range of clinical screening tools for detecting affected patients.
AB - Influenza viruses can cause epidemics through inter-human transmission, and the social consequences of viral transmission are incalculable. Current diagnostics for virus detection commonly relies on antibodies or nucleic acid as recognition reagent. However, a more advanced and general method for the facile development of new biosensors is increasing in demand. In this study, we report the fabrication of an ultra-sensitive peptide-based nanobiosensor using a nickel oxide (NiO)–reduced graphene oxide (rGO)/MXene nanocomposite to detect active influenza viruses (H1N1 and H5N2) and viral proteins. The sensing mechanism is based on the signal inhibition, the specific interaction between H1N1 (QMGFMTSPKHSV) and H5N1 (GHPHYNNPSLQL) binding peptides anchored on the NiO–rGO/MXene/glassy carbon electrode (GCE) surface and the viral surface protein hemagglutinin (HA) is the critical factor for the decrease in the peak current of the sensor. In this strategy, the NiO–rGO/MXene nanocomposite results in synergistic signal effects, including electrical conductivity, porosity, electroactive surface area, and active site availability when viruses are deposited on the electrode. Based on these observations, the results showed that the developed nanobiosensor was capable of highly sensitive and specific detection of their corresponding influenza viruses and viral proteins with a very low detection limit (3.63 nM of H1N1 and 2.39 nM for H5N1, respectively) and good recovery. The findings demonstrate that the proposed NiO–rGO/MXene-based peptide biosensor can provide insights for developing a wide range of clinical screening tools for detecting affected patients.
KW - Electrochemical biosensor
KW - Influenza virus
KW - MXene
KW - Recognition element
KW - Reduced graphene oxide
UR - https://www.scopus.com/pages/publications/85133644361
U2 - 10.1016/j.bios.2022.114511
DO - 10.1016/j.bios.2022.114511
M3 - Article
C2 - 35779412
AN - SCOPUS:85133644361
SN - 0956-5663
VL - 214
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
M1 - 114511
ER -