Fabrication of piezoresistive microcantilever using surface micromachining technique for biosensors

Kwang Ho Na, Yong Sang Kim, C. J. Kang

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

A microcantilever-based biosensor with piezoresistor has been fabricated using surface micromachining technique, which is cost effective and simplifies a fabrication procedure. In order to evaluate the characteristics of the cantilever, the cystamine terminated with thiol was covalently immobilized on the gold-coated side of the cantilever and glutaraldehyde that would be bonded with amine group in the cystamine was injected subsequently. This process was characterized by measuring the deflection of the cantilever in real time monitoring. Using a piezoresistive read-out and a well-known optical beam deflection method as well, the measurement of deflection was carried out. The sensitivity of piezoresistive method is good enough compared with that of optical beam deflection method.

Original languageEnglish
Pages (from-to)223-227
Number of pages5
JournalUltramicroscopy
Volume105
Issue number1-4
DOIs
StatePublished - Nov 2005
Externally publishedYes

Keywords

  • Biosensor
  • Microcantilever
  • Piezoresistive
  • Surface micromachining

Fingerprint

Dive into the research topics of 'Fabrication of piezoresistive microcantilever using surface micromachining technique for biosensors'. Together they form a unique fingerprint.

Cite this