Experimental study on pressure pulsation in piezo driven reed valve pump

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

In this study, we designed a reed valve pump using a piezoelectric device (PZT) as a power source and analyzed its performance. Numerical analysis and preliminary design were carried out in order to construct a pump chamber, and a valve port design was used so as to take advantage of the characteristics of a reed valve. The performance of the manufactured pump was investigated with glycerin solution, a working fluid. As expected, the flow rate of the pump increased with operating frequency as long as sufficient pressure relaxation could be given. From the measured results of the time resolved pressure, the maximum and minimum pressures were determined by the pressure relaxation. The investigation about the duty ratio of the square wave operation probed that the 50 % duty provided the maximum performance, and the duty ratio could be reduced at a high operating frequency without a performance reduction.

Original languageEnglish
Pages (from-to)661-667
Number of pages7
JournalJournal of Mechanical Science and Technology
Volume33
Issue number2
DOIs
StatePublished - 1 Feb 2019

Keywords

  • Membrane pump
  • Piezoelectric actuator
  • Pressure pulsation
  • Reed valve

Fingerprint

Dive into the research topics of 'Experimental study on pressure pulsation in piezo driven reed valve pump'. Together they form a unique fingerprint.

Cite this