Skip to main navigation Skip to search Skip to main content

Evaluation of the surface-guided radiotherapy workflow accuracy and plausibility of deep inspiration breath hold technique implementation: A phantom study

  • Kangbuk Samsung Hospital

Research output: Contribution to journal › Article › peer-review

Abstract

Introduction Deep inspiration breath-hold (DIBH) is widely used to reduce radiation exposure to the heart and lungs in patients with breast cancer. The integration of surface-guided radiation therapy (SGRT) with DIBH has gained attention, and several studies have explored its feasibility. This study aims to validate the workflow of the ExacTrac Dynamic (EXTD) system and evaluate its geometric accuracy in DIBH treatments. Methods The evaluation process for the EXTD system consisted of three steps. First, the reproducibility of the system's 3D structured light camera in restoring the original positioning was evaluated by measuring the positional differences in lateral, vertical, and longitudinal directions. Second, we calculated the geometric differences in positioning between image-guided radiation therapy (IGRT) and EXTD systems using various anatomical phantoms. Finally, the geometric differences between the EXTD contour-based DIBH system and a respiratory gating system (RGSC) were compared using a sinusoidal wave signal implemented in a 4D motion phantom. Results The EXTD's 3D structured light camera demonstrated high reproducibility in pre-positioning, with deviations of 0.3 mm laterally, 0.3 mm vertically, and 0.7 mm longitudinally. Geometric differences between the IGRT and EXTD systems were minimal, with deviations within 1 mm and 0.30° in the final patient setup. When compared with RGSC, the EXTD system exhibited comparable results with an R2 value of ≥0.97 with amplitude differences below 0.3 mm. Conclusions The EXTD system demonstrated excellent geometric accuracy and reliable respiratory tracking performance, supporting its suitability for DIBH treatments.

Original languageEnglish
Article number113624
JournalRadiation Physics and Chemistry
Volume242
DOIs
StatePublished - May 2026
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 4D motion phantom
  • Breast cancer
  • Deep inspiration breath hold
  • Image-guided radiotherapy
  • Surface-guided radiotherapy