Skip to main navigation Skip to search Skip to main content

Effect of the Automatic Needle Destroyer on Healthcare Providers’ Work in an Emergency Department: A Mixed-Methods Study

  • Sungkyunkwan University

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: This study introduced a novel Automatic Needle Destroyer (AND) to an emergency department (ED) and assessed its effect on healthcare providers’ work. Methods: Between August and September 2019, in the ED of a tertiary hospital in Seoul, we conducted a mixed-methods study to evaluate the efficiency, safety, and usability of the AND using video analysis, surveys, and in-depth interviews, wherein participants described the advantages and disadvantages of the AND. Results: Compared to the existing method, introducing the AND significantly reduced the operating time from 2.32 ± 1.14 seconds to 1.77 ± 3.71 seconds (p < 0.001). The normal operation rate was 90.6%. The rate of needle-stick injuries (NSIs) and the mean system usability scale (SUS) showed no significant differences. The in-depth interviews indicated that the disadvantages of the AND were mostly operational. The advantages were related to profit, reduced direct contact with hazardous waste, and behavioral changes, such as not having to recap syringes. Conclusions: We introduced the AND to an ED environment, where NSIs occur frequently and many syringes are used, to evaluate its effect on providers’ work. The AND reduced the time for needle disposal, but the normal operation rate was low. No significant differences were found in the SUS score or the rate of NSIs. Although there are some restrictions on introducing the AND immediately, this study’s results showed its potential usefulness. Efforts to improve the operation of the device and a longer study period are needed to fully achieve safety and efficiency.

Original languageEnglish
Pages (from-to)123-131
Number of pages9
JournalHealthcare Informatics Research
Volume28
Issue number2
DOIs
StatePublished - Apr 2022

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production

Keywords

  • Emergency Service
  • Feasibility Studies
  • Hospital
  • Needlestick Injuries
  • Occupational Health
  • Protective Devices

Fingerprint