Abstract
We investigated the dynamic characteristics of microfluidic systems under various operating conditions for micropump and microvalve. The pumping rates of the micropump are dependent on a frequency, a duty ratio of applied voltage, a poly(dimethylsiloxane) (PDMS) membrane thickness, and a channel depth. The maximum pumping rate of 64nl/min was obtained at the applied frequency of 5 Hz and duty ratio of 4% for a PDMS membrane thickness of 450 μm and a channel depth of 100 μm. The flow rates of the microvalve with a 300 μm PDMS membrane thickness are measured as a function of an applied power. The flow rate is easily controlled by the on/off alternation with the applied power of 400 mW. The in-channel structured PDMS micropump and microvalve are fabricated with the same fabrication procedure on the same substrate.
| Original language | English |
|---|---|
| Pages (from-to) | 519-522 |
| Number of pages | 4 |
| Journal | Japanese Journal of Applied Physics |
| Volume | 45 |
| Issue number | 1 B |
| DOIs | |
| State | Published - 20 Jan 2006 |
| Externally published | Yes |
Keywords
- ITO
- Micropump
- Microvalve
- PDMS
- Thermopneumatic-method
Fingerprint
Dive into the research topics of 'Dynamic characteristics of the micro-fluidic systems actuated by thermopneumatic-method'. Together they form a unique fingerprint.Cite this