TY - JOUR
T1 - Development of a highly sensitive lateral flow strip device for nucleic acid detection using molecular beacons
AU - Moon, Youngkwang
AU - Moon, Hyeokgyun
AU - Chang, Junhyuck
AU - Kim, Harold D.
AU - Lee, Jung Heon
AU - Lee, Jinkee
N1 - Publisher Copyright:
Copyright © 2022 Moon, Moon, Chang, Kim, Lee and Lee.
PY - 2022
Y1 - 2022
N2 - Extensive research is focused on the development of highly sensitive, rapid on-site diagnostic devices. The lateral flow strip (LFS) is a paper-based point-of-care diagnostic device, which is highly promising because of its ease of use and low cost. Despite these advantages, LFS device is still less popular than other methods such as enzyme-linked immunosorbent assay (ELISA) or real-time polymerase chain reaction (qPCR) due to its low sensitivity. Here, we have developed a fluorescence-based lateral flow strip (f-LFS) device for DNA detection using a molecular beacon (MB), a short hairpin-forming DNA strand tagged with a fluorophore-quencher pair. Each paper and membrane component of f-LFS device was carefully selected based on their physicochemical properties including porosity, surface functionality, and autofluorescence. The limit of detection (LOD) of this device was substantially improved to 2.1 fg/mL by adding MgCl2 to the reaction buffer and narrowing the test membrane dimension. Also, a portable fluorescence detection system for f-LFS was developed using a multi-pixel photon counter (MPPC), a sensitive detector detecting the signal on site. We anticipate that this highly sensitive paper-based diagnostic device can be utilized for on-site diagnosis of various diseases.
AB - Extensive research is focused on the development of highly sensitive, rapid on-site diagnostic devices. The lateral flow strip (LFS) is a paper-based point-of-care diagnostic device, which is highly promising because of its ease of use and low cost. Despite these advantages, LFS device is still less popular than other methods such as enzyme-linked immunosorbent assay (ELISA) or real-time polymerase chain reaction (qPCR) due to its low sensitivity. Here, we have developed a fluorescence-based lateral flow strip (f-LFS) device for DNA detection using a molecular beacon (MB), a short hairpin-forming DNA strand tagged with a fluorophore-quencher pair. Each paper and membrane component of f-LFS device was carefully selected based on their physicochemical properties including porosity, surface functionality, and autofluorescence. The limit of detection (LOD) of this device was substantially improved to 2.1 fg/mL by adding MgCl2 to the reaction buffer and narrowing the test membrane dimension. Also, a portable fluorescence detection system for f-LFS was developed using a multi-pixel photon counter (MPPC), a sensitive detector detecting the signal on site. We anticipate that this highly sensitive paper-based diagnostic device can be utilized for on-site diagnosis of various diseases.
KW - lateral flow strip (LFS)
KW - molecular beacon (MB)
KW - nucleic acid detection
KW - paper-based diagnostic device
KW - point-of-care (POC)
UR - https://www.scopus.com/pages/publications/85186889256
U2 - 10.3389/fsens.2022.1012775
DO - 10.3389/fsens.2022.1012775
M3 - Article
AN - SCOPUS:85186889256
SN - 2673-5067
VL - 3
JO - Frontiers in Sensors
JF - Frontiers in Sensors
M1 - 1012775
ER -