Skip to main navigation Skip to search Skip to main content

Corrosion detection system for thermally insulated pipeline buried in soil

  • Sungkyunkwan University
  • POSCO
  • Quality Technology Department

Research output: Contribution to specialist publicationArticle

Abstract

A resistance measurement system was used to detect wet areas of a thermally insulated pipeline in district heating systems. Sensor wire was embedded in the insulation to measure insulation resistance, which is related to moisture content and concentration of dissolved salts. The correlation between insulation resistance and corrosion rate was studied by direct current insulation resistance measurement and electrochemical techniques.

Original languageEnglish
Pages72-76
Number of pages5
Volume39
No7
Specialist publicationMaterials Performance
StatePublished - Jul 2000

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Fingerprint

Dive into the research topics of 'Corrosion detection system for thermally insulated pipeline buried in soil'. Together they form a unique fingerprint.