Abstract
A modified impact probe for continuous measurement of solids circulation rate in a circulating fluidized bed has been developed based on a principle similar to a momentum probe. The response curves of solid flow from the probe have been characterized and calibrated in a test column (0.05 m-I.D.×0.80 m-high). The probe was validated in situ in the downcomer of a circulating fluidized bed (0.10 m-I.D.×4.80 m-high). The solid circulation rates obtained by the modified impact probe well agree with the measured solids circulation rate by the descent time method.
| Original language | English |
|---|---|
| Pages (from-to) | 555-560 |
| Number of pages | 6 |
| Journal | Korean Journal of Chemical Engineering |
| Volume | 18 |
| Issue number | 4 |
| DOIs | |
| State | Published - Jul 2001 |
| Externally published | Yes |
Keywords
- Circulating fluidized beds
- Impact probe
- Solid circulation rate
- Solid flow measurement
Fingerprint
Dive into the research topics of 'Continuous Measurement of Solids Flow in a Circulating Fluidized Bed'. Together they form a unique fingerprint.Cite this