Complications after 100 sessions of cone-beam computed tomography-guided lung radiofrequency ablation: a single-center, retrospective experience

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Objective: To evaluate complications after consecutive 100 sessions of cone-beam computed tomography (CBCT)-guided radiofrequency ablation (RFA) of lung tumors Materials and methods: A retrospective study was conducted from January 2016 and October 2018. All procedures were performed using a CBCT virtual navigation guidance system, combining three-dimentional CBCT, needle planning software, and real-time fluoroscopy. Complications were evaluated for each RFA session in 63 consecutive patients (31 male, 32 female; mean age 58.0 years) with 121 lung tumors who underwent 100 sessions of CBCT-guided lung ablation with an internally cooled RFA system. Complications were recorded using the Common Terminology Criteria of Adverse Events (CTCAE) 5.0. A major complication was defined as a grade 3 or 4 adverse event. Results: There was no postprocedural mortality. The major and minor complication rates were 5% and 28%, respectively. The major complications were significant pulmonary hemorrhage (1%), large hemothorax requiring drainage (1%), pneumonia treated with antibiotics (2%), and delayed bronchopleural fistula (1%). The minor complications were pneumothorax (15%), hemoptysis (11%), and subcutaneous emphysema (2%). Of the 15 pneumothoraces, percutaneous catheter drainage was required in six sessions. Pneumothorax was more likely to occur if RFA was performed on two or more tumors at one session. Immediate, periprocedural and delayed complications were 23%, 9%, and 1%, respectively. Conclusion: CBCT-guided RFA of lung tumors is a relatively safe procedure with acceptable morbidity.

Original languageEnglish
Pages (from-to)763-771
Number of pages9
JournalInternational Journal of Hyperthermia
Volume37
Issue number1
DOIs
StatePublished - 1 Jan 2020
Externally publishedYes

Keywords

  • Complication
  • cone-beam computed tomography; virtual navigation guidance
  • lung neoplasms
  • radiofrequency ablation

Fingerprint

Dive into the research topics of 'Complications after 100 sessions of cone-beam computed tomography-guided lung radiofrequency ablation: a single-center, retrospective experience'. Together they form a unique fingerprint.

Cite this