T1 - Comparison of dual rotating Scheimpflug-Placido, swept-source optical coherence tomography, and Placido-scanning-slit systems
AU - Lee, Yong Woo
AU - Choi, Chul Young
AU - Yoon, Geun Young
N1 - Publisher Copyright:
© 2015 ASCRS and ESCRS.
PY - 2015/5/1
Y1 - 2015/5/1
N2 - Purpose To compare measurements of corneal indices using dual rotating Scheimpflug-Placido, swept-source optical coherence tomography (OCT), and Placido-scanning-slit systems. Setting Kangbuk Samsung Hospital, Seoul, South Korea. Design Prospective evaluation of diagnostic tests. Methods Corneal topography measurements were performed using dual rotating Scheimpflug-Placido (Galilei G2), swept-source OCT (Casia SS-1000), and Placido-scanning-slit (Orbscan IIz) systems. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the agreement between measurements. Results Fifty post-refractive surgery eyes and 50 normal eyes were evaluated. The agreement in anterior keratometry and pachymetry between the 3 devices was high in both groups (ICC > 0.9). In both groups, the ICC values for posterior keratometry and eccentricity were high between the dual rotating Scheimpflug-Placido and swept-source OCT systems (ICC > 0.9) but not between the Placido-scanning-slit system and the other 2 systems. The Placido-scanning-slit system yielded much steeper values for posterior keratometry in both groups (P <.05). The ICC values for posterior corneal elevation were lower than 0.9 between all 3 devices. The dual rotating Scheimpflug-Placido and swept-source OCT systems showed relatively higher ICC values than the Placido-scanning-slit system in both groups. Maximum posterior elevations were highest with the Placido-scanning-slit system followed by the swept-source OCT system and then the dual rotating Scheimpflug-Placido system. Conclusions Anterior keratometry obtained using 3 devices showed high degrees of agreement. Posterior keratometry and eccentricity showed greater agreement between the dual rotating Scheimpflug-Placido and swept-source OCT systems than with the Placido-scanning-slit system. The dual rotating Scheimpflug-Placido and swept-source OCT systems were equivalent in detecting the shape of the cornea and could be considered interchangeable. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
AB - Purpose To compare measurements of corneal indices using dual rotating Scheimpflug-Placido, swept-source optical coherence tomography (OCT), and Placido-scanning-slit systems. Setting Kangbuk Samsung Hospital, Seoul, South Korea. Design Prospective evaluation of diagnostic tests. Methods Corneal topography measurements were performed using dual rotating Scheimpflug-Placido (Galilei G2), swept-source OCT (Casia SS-1000), and Placido-scanning-slit (Orbscan IIz) systems. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the agreement between measurements. Results Fifty post-refractive surgery eyes and 50 normal eyes were evaluated. The agreement in anterior keratometry and pachymetry between the 3 devices was high in both groups (ICC > 0.9). In both groups, the ICC values for posterior keratometry and eccentricity were high between the dual rotating Scheimpflug-Placido and swept-source OCT systems (ICC > 0.9) but not between the Placido-scanning-slit system and the other 2 systems. The Placido-scanning-slit system yielded much steeper values for posterior keratometry in both groups (P <.05). The ICC values for posterior corneal elevation were lower than 0.9 between all 3 devices. The dual rotating Scheimpflug-Placido and swept-source OCT systems showed relatively higher ICC values than the Placido-scanning-slit system in both groups. Maximum posterior elevations were highest with the Placido-scanning-slit system followed by the swept-source OCT system and then the dual rotating Scheimpflug-Placido system. Conclusions Anterior keratometry obtained using 3 devices showed high degrees of agreement. Posterior keratometry and eccentricity showed greater agreement between the dual rotating Scheimpflug-Placido and swept-source OCT systems than with the Placido-scanning-slit system. The dual rotating Scheimpflug-Placido and swept-source OCT systems were equivalent in detecting the shape of the cornea and could be considered interchangeable. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
UR - https://www.scopus.com/pages/publications/84930607660
U2 - 10.1016/j.jcrs.2014.08.040
DO - 10.1016/j.jcrs.2014.08.040
M3 - Article
C2 - 26049835
AN - SCOPUS:84930607660
SN - 0886-3350
VL - 41
SP - 1018
EP - 1029
JO - Journal of Cataract and Refractive Surgery
JF - Journal of Cataract and Refractive Surgery
IS - 5
ER -