Skip to main navigation Skip to search Skip to main content

Comparable efficacy of a 1-L PEG and ascorbic acid solution administered with bisacodyl versus a 2-L PEG and ascorbic acid solution for colonoscopy preparation: A prospective, randomized and investigator-blinded trial

  • Ji Eun Kwon
  • , Jung Won Lee
  • , Jong Pil Im
  • , Ji Won Kim
  • , Su Hwan Kim
  • , Seong Joon Koh
  • , Byeong Gwan Kim
  • , Kook Lae Lee
  • , Sang Gyun Kim
  • , Joo Sung Kim
  • , Hyun Chae Jung
  • Armed Forces Capital Hospital
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

Abstract

Background Two liters of polyethylene glycol (PEG) solution administered with ascorbic acid (Asc) can provide efficacy similar to that of a 4-L PEG solution for colonoscopy preparation. In addition, oral bisacodyl (Bis) has been shown to reduce the volume of PEG needed fora bowel preparation with comparable efficacy. This study aimed to compare the efficacy, tolerability and safety of a 2-L PEG solution mixed with Asc versus the combination of Bis, Asc and a 1-L PEG solution. Methods This was a prospective, randomized, multi-centre, single-blind, non-inferiority trial. Participants who were scheduled for colonoscopy were included and randomized to receive either 2-L PEG and Asc (2L PEG/Asc group) or 1-L PEG, Asc and 20 mg Bis (1L PEG/Asc + Bis group). The quality of bowel preparation was assessed using the Boston Bowel Preparation Scale. Data regarding tolerance, compliance and adverse events were also gathered. Results A total of 187 participants were analyzed; 96 were allocated to the 2L PEG/Asc group and 91 to the 1L PEG/Asc + Bis group. Bowel preparation was adequate in 87.5% (84/96) of patients in the 2L PEG/Asc group and 94.5% of the 1L PEG/Asc + Bis group (86/91, p = 0.10). There was no significant difference between the two groups with respect to compliance, tolerability or safety. The patients allocated to the 1L PEG/Asc + Bis group expressed more willingness to repeat the procedure than patients in the 2L PEG/Asc group (p = 0.01). Conclusions Bowel preparation with Bis and a 1-L PEG/Asc solution is as effective, well-tolerated, and safe as a 2-L PEG/Asc solution.

Original languageEnglish
Article numbere0162051
JournalPLoS ONE
Volume11
Issue number9
DOIs
StatePublished - Sep 2016
Externally publishedYes

Fingerprint

Dive into the research topics of 'Comparable efficacy of a 1-L PEG and ascorbic acid solution administered with bisacodyl versus a 2-L PEG and ascorbic acid solution for colonoscopy preparation: A prospective, randomized and investigator-blinded trial'. Together they form a unique fingerprint.

Cite this