Abstract
The rapid antigen test (RAT) for coronavirus disease (COVID-19) represents a potent diagnostic method in situations of limited molecular testing resources. However, considerable performance variance has been reported with the RAT. We evaluated the clinical performance of Standard Q COVID-19 RAT (SQ-RAT; SD Biosensor, Suwon, Korea), the first RAT approved by the Korean Ministry of Food and Drug Safety. In total, 680 nasopharyngeal swabs previously tested using real-time reverse-transcription PCR (rRT-PCR) were retested using SQ-RAT. The clinical sensitivity of SQ-RAT relative to that of rRT-PCR was 28.7% for all specimens and was 81.4% for specimens with RNA-dependent RNA polymerase gene (RdRp) threshold cycle (Ct) values ≤23.37, which is the limit of detection of SQ-RAT. The specificity was 100%. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis was assessed based on the Ct distribution at diagnosis of 33,294 COVID-19 cases in Korea extracted from the laboratory surveillance system of Korean Society for Laboratory Medicine. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis in the Korean population was 41.8%. Considering the molecular testing capacity in Korea, use of the RAT for COVID-19 diagnosis appears to be limited.
| Original language | English |
|---|---|
| Pages (from-to) | 588-592 |
| Number of pages | 5 |
| Journal | Annals of Laboratory Medicine |
| Volume | 41 |
| Issue number | 6 |
| DOIs | |
| State | Published - 2021 |
Keywords
- Coronavirus disease
- Korea
- Laboratory surveillance
- Rapid antigen test
- Real-time reverse-transcription PCR