Skip to main navigation Skip to search Skip to main content

Characterization of benign and malignant solid breast masses: Comparison of conventional US and tissue harmonic imaging

  • Joo Hee Cha
  • , Woo Kyung Moon
  • , Nariya Cho
  • , Sun Mi Kim
  • , Seong Ho Park
  • , Boo Kyung Han
  • , Yeon Hyeon Choe
  • , Jeong Mi Park
  • , Jung Gi Im
  • Seoul National University
  • University of Ulsan
  • Sungkyunkwan University
  • University of Iowa

Research output: Contribution to journal › Review article › peer-review

Abstract

Purpose: To prospectively compare the diagnostic performance of radiologists by using conventional ultrasonography (US) and tissue harmonic imaging for the differentiation of benign from malignant solid breast masses, with histologic results used as the reference standard. Materials and Methods: The study was approved by the institutional review board, and informed consent was obtained from all patients. Images were obtained with, conventional US and tissue harmonic imaging in 88 patients (age range, 25-67 years; mean age, 45 years), with 91 solid breast masses (30 cancers and 61 benign lesions) before excisional or needle biopsy. Three experienced radiologists, who did not perform the examinations, independently analyzed the US findings and provided a level of suspicion to indicate the probability of malignancy. Results were evaluated by using κ statistics and receiver operating characteristic (ROC) analyses. Results: Regarding the descriptions of US findings, echogenicity (κ = 0.205) was the most discordant between conventional US and tissue harmonic imaging, followed by margin (κ = 0.495), lesion boundary (κ = 0.495), calcifications (κ = 0.537), posterior acoustic transmission (κ = 0.546), echotexture (κ = 0.586), shape (κ = 0.591), and orientation (κ = 0.594). The area under the ROC curve (Az) for conventional US and tissue harmonic imaging was 0.84 and 0.79, respectively, for reader 1; 0.88 and 0.85, respectively, for reader 2; and 0.91 and 0.89, respectively, for reader 3. The overall Az value for the three readers was 0.88 for conventional US and 0.84 for tissue harmonic imaging (95% confidence interval: -0.0950, 0.1646; P = .595). Conclusion: The performance of the radiologists with respect to the characterization of solid breast masses as benign or malignant was not significantly improved with tissue harmonic imaging.

Original languageEnglish
Pages (from-to)63-69
Number of pages7
JournalRadiology
Volume242
Issue number1
DOIs
StatePublished - Jan 2007

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Characterization of benign and malignant solid breast masses: Comparison of conventional US and tissue harmonic imaging'. Together they form a unique fingerprint.

Cite this