Characterization of a compressed sensing PET detector and data acquisition system: Effects of multiplexing and sampling rate

Chen Ming Chang, Alexander M. Grant, Brian J. Lee, Craig S. Levin

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Reducing the number of readout channels of PET detectors with multiplexing can save the cost and complexity for developing a scanner. However, a high multiplexing ratio can also degrade the signal-to-noise (SNR) ratio of the detector since the noise of the multiplexed channels is summed together. Compressed sensing (CS) was recently shown to be a promising multiplexing method for PET detectors that can achieve high multiplexing ratio while resolving simultaneous hits on multiple pixels with high SNR recovery for PET detectors. In this work, we study the effects of multiplexing and sampling rate on the performance of the CS detectors and the corresponding DAQ system we have developed for a PET insert for simultaneous PET/MR brain imaging. The coincidence time resolution acquired by a pair of single-crystal detectors degraded from 1.4 ns to 3.2 ns when the sampling rate dropped from 20GHz (sampled by the digital oscilloscope) to 65MHz (sampled by the 256-channel DAQ system developed in house). The coincidence time resolution further degraded to 3.7 ns when the coincidence events were acquired by two CS detectors (with a multiplexing ratio of 8:1) and sampled by the DAQ system, indicating the effect of multiplexing on the timing performance. Possible future studies to diagnose and mitigate the causes of timing performance degradation are discussed.

Original languageEnglish
Title of host publication2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781479960972
DOIs
StatePublished - 10 Mar 2016
Externally publishedYes
EventIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 - Seattle, United States
Duration: 8 Nov 201415 Nov 2014

Publication series

Name2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014

Conference

ConferenceIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
Country/TerritoryUnited States
CitySeattle
Period8/11/1415/11/14

Fingerprint

Dive into the research topics of 'Characterization of a compressed sensing PET detector and data acquisition system: Effects of multiplexing and sampling rate'. Together they form a unique fingerprint.