Skip to main navigation Skip to search Skip to main content

Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab

  • (Muon g-2 Collaboration)
  • University of Liverpool
  • National Institute for Nuclear Physics
  • Fermi National Accelerator Laboratory
  • University of Virginia
  • Oak Ridge National Laboratory
  • Lancaster University
  • Cockcroft Institute
  • Joint Institute for Nuclear Research
  • University of Illinois at Urbana-Champaign
  • Cornell University
  • Michigan State University
  • University of Mississippi
  • University of Washington
  • North Central College
  • University of Pisa
  • University of Trieste
  • Boston University
  • University of Udine
  • University of Kentucky
  • Institute for Basic Science
  • Korea Advanced Institute of Science and Technology
  • University College London
  • Shanghai Jiao Tong University
  • Astrophysics and Cosmology (MOE)
  • Shanghai Key Laboratory for Particle Physics and Cosmology
  • University of Michigan, Ann Arbor
  • Argonne National Laboratory
  • Brookhaven National Laboratory
  • P.N. Lebedev Physical Institute of the Russian Academy of Sciences
  • University of Cassino and Southern Lazio
  • Northern Illinois University
  • National Research Council of Italy
  • Johannes Gutenberg University Mainz
  • University of Massachusetts

Research output: Contribution to journal › Article › peer-review

Abstract

This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 dataset of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency ωam are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary, because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to ωam is 0.50±0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of ωam.

Original languageEnglish
Article number044002
JournalPhysical Review Accelerators and Beams
Volume24
Issue number4
DOIs
StatePublished - Apr 2021
Externally publishedYes

Fingerprint

Dive into the research topics of 'Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab'. Together they form a unique fingerprint.

Cite this