TY - JOUR
T1 - Automated versus conventional microscopic interpretation of antinuclear antibody indirect immunofluorescence test
AU - Park, Yumi
AU - Kim, Seon Young
AU - Kwon, Gye Cheol
AU - Koo, Sun Hoe
AU - Kang, Eun Suk
AU - Kim, Jimyung
N1 - Publisher Copyright:
© 2019 by the Association of Clinical Scientists, Inc.
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Background. The detection of antinuclear antibodies (ANAs) is crucial for the diagnosis of systemic autoimmune rheumatic diseases. Here, we evaluated the performance of an automated ANA image analyzer, EUROPattern Suite. Methods. We compared the automated and manually revised interpretations of EUROPattern Suite with conventional microscopic interpretations of indirect immunofluorescence (IIF) by calculating the analytical sensitivity and specificity for ANA detection and evaluating the concordance between these approaches for ANA detection, pattern recognition, and titer determination. Results. The analytical sensitivity and specificity of EUROPattern Suite for ANA detection were 97.7% and 88.2%, respectively, relative to those of conventional IIF, with a concordance of 94.4% 3κ=0.874). After manual revision, the analytical sensitivity, specificity, and concordance improved to 98.5%, 94.1%, and 97.0% (κ=0.932), respectively. The concordance rates for pattern recognition with simple and mixed patterns were 72.1% and 56.0%, respectively, and varied depending on the type of pattern. After manual revision, the concordance rates with simple and mixed patterns increased to 97.1% and 84.0%, respectively. The concordance rate for titer determination with a simple pattern was 84.6%. Conclusion. Although automated pattern recognition has some limitations, EUROPattern Suite facilitates automated ANA detection with a high sensitivity and concordance with conventional IIF.
AB - Background. The detection of antinuclear antibodies (ANAs) is crucial for the diagnosis of systemic autoimmune rheumatic diseases. Here, we evaluated the performance of an automated ANA image analyzer, EUROPattern Suite. Methods. We compared the automated and manually revised interpretations of EUROPattern Suite with conventional microscopic interpretations of indirect immunofluorescence (IIF) by calculating the analytical sensitivity and specificity for ANA detection and evaluating the concordance between these approaches for ANA detection, pattern recognition, and titer determination. Results. The analytical sensitivity and specificity of EUROPattern Suite for ANA detection were 97.7% and 88.2%, respectively, relative to those of conventional IIF, with a concordance of 94.4% 3κ=0.874). After manual revision, the analytical sensitivity, specificity, and concordance improved to 98.5%, 94.1%, and 97.0% (κ=0.932), respectively. The concordance rates for pattern recognition with simple and mixed patterns were 72.1% and 56.0%, respectively, and varied depending on the type of pattern. After manual revision, the concordance rates with simple and mixed patterns increased to 97.1% and 84.0%, respectively. The concordance rate for titer determination with a simple pattern was 84.6%. Conclusion. Although automated pattern recognition has some limitations, EUROPattern Suite facilitates automated ANA detection with a high sensitivity and concordance with conventional IIF.
UR - https://www.scopus.com/pages/publications/85062381282
M3 - Article
C2 - 30814088
AN - SCOPUS:85062381282
SN - 0091-7370
VL - 49
SP - 127
EP - 133
JO - Annals of Clinical and Laboratory Science
JF - Annals of Clinical and Laboratory Science
IS - 1
ER -