Skip to main navigation Skip to search Skip to main content

Association of Breast Tissue Composition on Preoperative Automated Breast Ultrasound With Accuracy of Cancer Multiplicity Evaluation and Recurrence-Free Survival in Patients With Early-Stage Breast Cancer

  • Konkuk University
  • Ewha Womans University

Research output: Contribution to journal › Article › peer-review

Abstract

Objective: To investigate whether breast tissue composition on preoperative automated breast ultrasound (ABUS) is associated with the accuracy of cancer multiplicity evaluation and postoperative recurrence-free survival (RFS) in patients with early-stage breast cancer. Materials and Methods: This retrospective analysis included women with early-stage breast cancer (clinical Tis, T1–2/N0) who underwent ABUS and digital mammography (DM) between October 2019 and April 2021. Tissue composition on ABUS was assessed using the Breast Imaging Reporting and Data System background echotexture (BE) (homogeneous-fat, homogeneous-fibroglandular, or heterogeneous). In a subgroup of patients with mammographically dense breasts, the glandular tissue component (GTC) on ABUS were further stratified into high (moderate or marked) or low (minimal or mild). Multivariable logistic and Cox regression analyses were used to identify factors associated with accurate cancer multiplicity categorization (unifocal, multifocal/multicentric, or bilateral) using ABUS + DM, and with RFS, respectively. Results: Among 409 women (mean age ± standard deviation, 50.2 ± 8.7 years), ABUS combined with DM yielded accurate cancer multiplicity categorization in 368 patients (90.0%). Neither BE nor GTC on ABUS affected the accuracy of categorization when ABUS was combined with DM. Over a median postoperative follow-up of 3.5 years, 11 recurrences occurred. Heterogeneous BE on ABUS (hazard ratio [HR] 11.24 [95% confidence interval [CI]: 2.82–44.92]; P = 0.001), BRCA mutation (HR 15.94 [2.47–102.97]; P = 0.004), and pathologic index cancer size (HR per 1-cm increase 1.91 [1.13–3.23]; P = 0.02) was independently associated with RFS. In patients with dense breasts, heterogeneous BE (HR 14.17 [95% CI: 2.69–74.60]; P = 0.002) and high GTC (HR 10.32 [2.35–45.28]; P = 0.002) on ABUS, BRCA mutation (HR 24.34 [2.75– 215.06]; P = 0.004), and pathologic cancer size (HR per 1-cm increase 2.62 [1.50–4.59]; P = 0.001) was independently associated with RFS. Conclusion: In patients with early-stage breast cancer, heterogeneous BE and high GTC on preoperative ABUS, along with larger cancer size and BRCA mutation, was associated with worse RFS. However, BE and GTC did not affect cancer multiplicity evaluation when ABUS was used in combination with DM.

Original languageEnglish
Pages (from-to)97-110
Number of pages14
JournalKorean Journal of Radiology
Volume27
Issue number2
DOIs
StatePublished - 1 Feb 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Breast cancer
  • Echotexture
  • Glandular tissue component
  • Tissue composition
  • US

Fingerprint

Dive into the research topics of 'Association of Breast Tissue Composition on Preoperative Automated Breast Ultrasound With Accuracy of Cancer Multiplicity Evaluation and Recurrence-Free Survival in Patients With Early-Stage Breast Cancer'. Together they form a unique fingerprint.

Cite this