Skip to main navigation Skip to search Skip to main content

Are loose-fitting powered air-purifying respirators safe during chest compression? A simulation study

  • Sungkyunkwan University

Research output: Contribution to journal › Article › peer-review

Abstract

Background: The application of appropriate personal protective equipment for respiratory protection to health care workers is a cornerstone for providing safe healthcare in emergency departments. We investigated the protective effect and usefulness of loose-fitting powered air-purifying respirators (PAPRs) during chest compression. Methods: This was a single-center simulation study performed from May 2019 to July 2019 in a tertiary hospital. We measured the concentrations of ambient aerosol and particles inside the loose-fitting PAPR during chest compression, and this ratio was set as the simulated workplace protecting factor (SWPF). According to the National Institute for Occupational Safety and Health regulations, the assigned protection factor (APF) of loose-fitting PAPRs is 25. Thus, the loose-fitting PAPRs were assumed to have a protective effect when the SWPF were ≥ 250 (APF × 10). We measured the SWPF of PAPR in real time during chest compression and also investigated the problems encountered during its use. Results: Ninety-one participants (median age 29 [interquartile range (IQR): 26–32] years; 74% female) completed the simulation. None of the participants failed with SWPF below 250 during three sessions of chest compression. The median (IQR) values of SWPF at three cycles were 17,063 (10,145-26,373), 15,683 (9477-32,394), and 16,960 (7695-27,279). There was no disconnection of equipment or mechanical failures during chest compression. In addition, most participants (83%) replied that they rarely or never experienced difficulty in verbal communication and felt that the loose-fitting PAPR was comfortable. Conclusions: The loose-fitting PAPRs provided sufficient respiratory protection without disturbances during chest compression.

Original languageEnglish
Pages (from-to)235-240
Number of pages6
JournalAmerican Journal of Emergency Medicine
Volume44
DOIs
StatePublished - Jun 2021
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 8 - Decent Work and Economic Growth
    SDG 8 Decent Work and Economic Growth

Keywords

  • Cardiopulmonary resuscitation
  • Chest
  • Compression
  • Infection control
  • Respiratory protective devices

Fingerprint

Dive into the research topics of 'Are loose-fitting powered air-purifying respirators safe during chest compression? A simulation study'. Together they form a unique fingerprint.