Skip to main navigation Skip to search Skip to main content

Accurate measurement of respiratory airway wall thickness in CT images using a signal restoration technique

  • Joon Park Sang
  • , Jung Kim Tae
  • , Gi Kim Kwang
  • , Ho Lee Sang
  • , Mo Goo Jin
  • , Hyo Kim Jong
  • Seoul National University
  • National Cancer Center Korea

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

Abstract

Airway wall thickness (AWT) is an important bio-marker for evaluation of pulmonary diseases such as chronic bronchitis, bronchiectasis. While an image-based analysis of the airway tree can provide precise and valuable airway size information, quantitative measurement of AWT in Multidetector-Row Computed Tomography (MDCT) images involves various sources of error and uncertainty. So we have developed an accurate AWT measurement technique for small airways with three-dimensional (3-D) approach. To evaluate performance of these techniques, we used a set of acryl tube phantom was made to mimic small airways to have three different sizes of wall diameter (4.20, 1.79, 1.24 mm) and wall thickness (1.84, 1.22, 0.67 mm). The phantom was imaged with MDCT using standard reconstruction kernel (Sensation 16, Siemens, Erlangen). The pixel size was 0.488 mm × 0.488 mm × 0.75 mm in x, y, and z direction respectively. The images were magnified in 5 times using cubic B-spline interpolation, and line profiles were obtained for each tube. To recover faithful line profile from the blurred images, the line profiles were deconvolved with a point spread kernel of the MDCT which was estimated using the ideal tube profile and image line profile. The inner diameter, outer diameter, and wall thickness of each tube were obtained with full-width-half-maximum (FWHM) method for the line profiles before and after deconvolution processing. Results show that significant improvement was achieved over the conventional FWHM method in the measurement of AWT.

Original languageEnglish
Title of host publicationMedical Imaging 2008 - Physics of Medical Imaging
DOIs
StatePublished - 2008
Externally publishedYes
EventMedical Imaging 2008 - Physics of Medical Imaging - San Diego, CA, United States
Duration: 18 Feb 2008 → 21 Feb 2008

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6913
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2008 - Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period18/02/08 → 21/02/08

Keywords

  • Airway
  • Deconvolution
  • MDCT
  • Phantom validation
  • Super sampling
  • Three dimensional
  • Wall thickness

Fingerprint

Dive into the research topics of 'Accurate measurement of respiratory airway wall thickness in CT images using a signal restoration technique'. Together they form a unique fingerprint.

Cite this