TY - JOUR
T1 - Accurate and Rapid Measurement of Glycated Hemoglobin Using HLC-723 G11 Variant Mode
AU - Park, Min Seung
AU - Lee, Kyunghoon
AU - Song, Junghan
AU - Park, Hyung Doo
N1 - Publisher Copyright:
© 2019 Seoul National University Institute for Cognitive Science. All Rights Reserved.
PY - 2019
Y1 - 2019
N2 - Background: Type II diabetes mellitus causes many complications, and its prevalence con-tinues to increase in Korea. Accurate measurement of glycated Hb (HbA1c) is important because of its usefulness in diagnosis, follow-up, and prediction of prognosis. We tested the analytical performance of the HLC-723 G11 Variant Mode (G11vr; Tosoh Bioscience, Inc., Tokyo, Japan), recently introduced to Korea, in detecting HbA1c. Methods: We evaluated precision, linearity, carry-over, and turnaround time. Using 208 samples, including 108 flagged samples, we compared HbA1c concentrations from four analyzers through correlation analysis: G11vr, HLC-723 G8 Variant Mode (G8vr, Tosoh Bioscience), HLC-723 G11 Standard Mode (G11st, Tosoh Bioscience), and HLC-723 G8 Standard Mode (G8st, Tosoh Bioscience). We used HPLC mass spectrometry (MS) and capil-lary electrophoresis (CE) to confirm the HbA1c concentrations of 15 additional known Hb variant samples. Results: Repeatability (% CV) in measuring low- and high-concentration controls was 0.57% and 0.35%, respectively; within-laboratory precision was 0.86% and 0.69%, respectively. In a linearity test, the coefficient of determination was 0.9999 (measurement range: 3.64% to 18.59%) for HbA1c. The correlations between G11vr and other analyzers were weaker for flagged samples than for non-flagged samples. The carry-over effect was less than 0.4%. Turnaround time for a single sample was lower in G11vr (one minute) than in G8vr (1.6 minutes). For 15 samples with Hb variants, G11vr HbA1c results were more similar than those of other analyzers to HPLC-MS and CE results. Conclusions: G11vr showed adequate performance and rapid turnaround time in measur-ing HbA1c.
AB - Background: Type II diabetes mellitus causes many complications, and its prevalence con-tinues to increase in Korea. Accurate measurement of glycated Hb (HbA1c) is important because of its usefulness in diagnosis, follow-up, and prediction of prognosis. We tested the analytical performance of the HLC-723 G11 Variant Mode (G11vr; Tosoh Bioscience, Inc., Tokyo, Japan), recently introduced to Korea, in detecting HbA1c. Methods: We evaluated precision, linearity, carry-over, and turnaround time. Using 208 samples, including 108 flagged samples, we compared HbA1c concentrations from four analyzers through correlation analysis: G11vr, HLC-723 G8 Variant Mode (G8vr, Tosoh Bioscience), HLC-723 G11 Standard Mode (G11st, Tosoh Bioscience), and HLC-723 G8 Standard Mode (G8st, Tosoh Bioscience). We used HPLC mass spectrometry (MS) and capil-lary electrophoresis (CE) to confirm the HbA1c concentrations of 15 additional known Hb variant samples. Results: Repeatability (% CV) in measuring low- and high-concentration controls was 0.57% and 0.35%, respectively; within-laboratory precision was 0.86% and 0.69%, respectively. In a linearity test, the coefficient of determination was 0.9999 (measurement range: 3.64% to 18.59%) for HbA1c. The correlations between G11vr and other analyzers were weaker for flagged samples than for non-flagged samples. The carry-over effect was less than 0.4%. Turnaround time for a single sample was lower in G11vr (one minute) than in G8vr (1.6 minutes). For 15 samples with Hb variants, G11vr HbA1c results were more similar than those of other analyzers to HPLC-MS and CE results. Conclusions: G11vr showed adequate performance and rapid turnaround time in measur-ing HbA1c.
KW - Glycated hb
KW - Hb variants
KW - Hba1c
KW - Performance
KW - Tosoh hlc-723 g11 analyzer
UR - https://www.scopus.com/pages/publications/85059795096
U2 - 10.3343/alm.2019.39.3.243
DO - 10.3343/alm.2019.39.3.243
M3 - Article
AN - SCOPUS:85059795096
SN - 2234-3806
VL - 39
SP - 243
EP - 250
JO - Annals of Laboratory Medicine
JF - Annals of Laboratory Medicine
IS - 3
ER -