AC loss measurement of Bi-2223 conductors

  • Mi Hye Jang
  • , Yong Chu
  • , Tae Kuk Ko
  • , Sang Soo Oh
  • , Jin Ho Joo

Research output: Contribution to journalConference articlepeer-review

1 Scopus citations

Abstract

In this paper, AC losses of Bi-2223 tapes with different matrix of superconducting core were measured and analysed. The two samples produced by a powder-in-tube method are multi-filamentary tape with AG and Ag-Au matrix. The measurement was carried out under the environment of constant transport current and applied time-varying magnetic field. From experiment, losses for fields applied parallel to the c-axis of the textured Bi-2223 grains are larger by over an order of magnitude than those applied perpendicular. And it is confirmed that conductor losses with Ag matrix are larger than those with Ag-Au matrix.

Original languageEnglish
Pages (from-to)2575-2576
Number of pages2
JournalPhysica C: Superconductivity and its Applications
Volume341-348 (IV)
DOIs
StatePublished - Nov 2000
EventInternational Conference on Materials and Mechanisms of Superconductivity High Temperature Superconductors VI - Houston, TX, USA
Duration: 20 Feb 200025 Feb 2000

Fingerprint