Skip to main navigation Skip to search Skip to main content

A novel robotic surgical technique for thyroid surgery: bilateral axillary approach (BAA)

  • Sungkyunkwan University
  • Gyeongsang National University

Research output: Contribution to journal › Article › peer-review

Abstract

Introduction: Bilateral axillo-breast approach (BABA) robotic thyroidectomy (RT) is proven to be a feasible method for the treatment of well-differentiated thyroid cancers in terms of oncology as well as cosmesis. However, BABA RT causes postoperative sternal discomfort and needs an incision over the nipple areolar area. Here, we suggest a novel robotic surgical technique for thyroid surgery that does not need a breast incision—bilateral axillary approach (BAA). Patients and methods: We recruited 51 patients who were willing to undergo the novel BAA robotic thyroid surgery. We performed a propensity score-matched analysis to compare the BAA robotic thyroid surgery group (BAA group) with the conventional open thyroid surgery group (open group). Results: Mean operation time in the BAA group (129.7 min) was significantly longer than that in the open group (103.1 min) (p < 0.001). However, no significant differences in the mean number of metastatic lymph nodes (LNs), mean number of retrieved LNs, vocal cord palsy, hypoparathyroidism, and mean stimulated thyroglobulin level were observed between the two groups. There was no case of postoperative bleeding or chyle leak. Of the 51 patients who had undergone the BAA procedure, 27 patients answered the questionnaire. The mean scale, ranging from 0 to 10, at postoperative 1 day/2 weeks was as follows: voice change score, 3.0/1.6; swallowing difficulty score, 4.0/2.0; anterior neck pain score, 4.6/3.6; anterior neck numbness score, 5.4/4.3; right chest pain score, 3.8/2.1; left chest pain score, 3.6/2.3; right chest numbness score, 3.2/2.8; left chest numbness score, 2.4/2.7; right breast pain score, 0.9/0; left breast pain score, 1.2/0; right breast numbness score, 1.7/0; and left breast numbness score, 2.6/0, respectively. Conclusion: BAA robotic thyroid surgery is a novel, safe, and feasible oncoplastic method, especially for patients who have fear of procedures around the nipple areolar complex.

Original languageEnglish
Pages (from-to)667-672
Number of pages6
JournalSurgical Endoscopy
Volume31
Issue number2
DOIs
StatePublished - 1 Feb 2017

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bilateral axillary approach
  • Robotic thyroid surgery
  • Robotic thyroidectomy

Fingerprint

Dive into the research topics of 'A novel robotic surgical technique for thyroid surgery: bilateral axillary approach (BAA)'. Together they form a unique fingerprint.

Cite this