Abstract
A 7-MHz integrated peak-current-mode buck regulator with a charge-recycling technique and a fast response current-sensing circuit is proposed. The proposed chargerecycling technique contributes to the improvement of the light load efficiency by up to 1.7% for the proposed buck regulator. Moreover, the proposed buck regulator achieves a fast response time of less than 10 ns with a fast response current-sensing circuit. Applying the proposed charge-recycling technique and the current-sensing circuit, the peak-current-mode buck regulator for the mobile application is realized with an operating frequency of 7 MHz, an output voltage of 0.8 V, a maximum load current of 500 mA, and a peak efficiency of over 77%.
| Original language | English |
|---|---|
| Pages (from-to) | 797-801 |
| Number of pages | 5 |
| Journal | IEEE Transactions on Circuits and Systems II: Express Briefs |
| Volume | 64 |
| Issue number | 7 |
| DOIs | |
| State | Published - Jul 2017 |
Keywords
- Charge-recycling technique
- Current-mode buck regulator
- Fast response current sensor
- High frequency buck regulator
Fingerprint
Dive into the research topics of 'A 7-MHz integrated peak-current-mode buck regulator with a charge-recycling technique'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver