3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: Comparison study with 3D isotropic fast-field echo sequence

  • Sungkyunkwan University

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Three-dimensional (3D) turbo spin-echo (TSE) images have been used in imaging of the extremities and comparable diagnostic performance to two-dimensional (2D) TSE images has been reported in several studies. However, comparison of the 3D isotropic TSE intermediate-weighted sequence and 3D FFE sequence in terms of image quality has not been investigated. Purpose: To compare the image quality of a 3D isotropic TSE intermediate-weighted sequence with refocusing control (volume isotropic turbo spin echo acquisition [VISTA]) and a 3D isotropic fast-field echo (FFE) sequence of the knee joint. Material and Methods: 3.0 T knee MRI with VISTA and 3D FFE sequences was performed in 10 healthy volunteers (3 men, 7 women; age range 26-30 years). Two radiologists with specialties in the musculoskeletal system assessed tissue contrast between the fluid-cruciate ligament (F-L), fluid-meniscus (F-M), and fluid-cartilage (F-C) based on a 4-point scale (1, poor;2, fair;3, good; and 4, excellent). Statistical analysis for inter-observer agreement and differences in grades in tissue contrast between VISTA and 3D FFE images (Wilcoxon signed-rank) were performed. For a quantitative analysis, the signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Image contrast ratios (CRs) were calculated between F-L, F-M, and F-C in volunteer images of VISTA and 3D FFE and compared statistically with a paired t-test. Results: Based on qualitative analysis, VISTA had statistically superior grades of tissue contrast in F-L (P <0.001) and F-M (P <0.001). 3D FFE had superior but not statistically significant (P = 0.317) grades in F-C. Based on quantitative analysis, the SNR of the phantom imaging was higher in VISTA than that in 3D FFE (28.18 vs. 14.90). VISTA had superior CRs in F-L (P <0.001) and F-M (P <0.001). 3D FFE had superior CR in F-C (P = 0.038). Conclusion: The VISTA sequence was superior in tissue contrast between F-M and F-L, and 3D FFE was superior in tissue contrast between F-C, subjectively and quantitatively.

Original languageEnglish
Pages (from-to)1119-1124
Number of pages6
JournalActa Radiologica
Volume52
Issue number10
DOIs
StatePublished - Dec 2011

Keywords

  • Knee
  • MR imaging
  • Skeletal-appendicular

Fingerprint

Dive into the research topics of '3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: Comparison study with 3D isotropic fast-field echo sequence'. Together they form a unique fingerprint.

Cite this